TH131 & TH133
User Guide
Electronic Thermostat
TH131
Pilot wire indicator (Europe only)
Heating indicator
On/Off switch
Temperature selection dial
oInstallation
Control Module
TH133
Front View | Rear View |
NOTE: Even if the following illustrations show the TH131 model only, they can also apply to the TH133 model.
nDescription
This user guide covers the following thermostat models:
•TH131 A/F/AF
•TH133 A/F/AF
The TH131 model is designed for residential applications, whereas the TH133 model is designed for public areas as its controls are hid- den and thus protected against unauthorized access. Both models can be configured for the following applications:
Type | Application |
AControls the ambient (room) temperature F Controls the floor temperature
AF | Controls the ambient temperature and limits the floor temperature |
Power Base
NOTE: Keep the thermostat's air vents clean and free from obstruc- tions.
pConfiguration
3.1Application Types
Type | Switch Position |
|
|
A | UP (A/AF) |
|
|
AF | UP (A/AF) |
|
|
F | DOWN (F) |
|
|
Position the switch, on the back of the control module, according to your application.
3.2Minimum and Maximum Limits (TH131 only)
Use the two potentiometers on the
back of the control module to set | notches |
the minimum and maximum tem- perature limits. Depending on your application, the potentiometers limit the following temperature:
ambient temperature (A) floor temperature (F or AF)
Use a