TH146-P-2H1C

User’s Guide

Programmable H/C Controller

Time and day setting

Programming

Program day selection

Program clear

Humidity setting Return

Indicator LEDs

Temperature adjustment mode selection

Fan operating mode selection

System operating mode selection

Up/Down buttons

Indicator LEDs

FAULT: System fault

EH: Emergency heat mode

DE: Dual energy

Backlight

The screen is lit for 12 seconds when any button is pressed. However, the screen remains lit while you are configuring the controller.

Day

Clock

Indoor temperature

Indoor humidity

Outdoor temperature

5. General Setting

5.1 Clock and Day Setting

6.Temperature Setting

6.1 Display

nPress Clk. The hour display flashes. o Set the hour using .

p Press Clk. The minute display flashes. q Set the minutes using .

r Press Clk. The day display flashes. s Set the day using .

t Press

 

to return to the normal display.

 

 

5.2 Date Setting

n

Press Clk for 3 seconds to display the year.

o

Set the year using

.

Appears when the temperature setpoint is displayed

Heating is On

Auxiliary heating is On

Temperature adjustment mode (appears when the system is in automatic mode, disappears when it is in manual mode)

Indoor temperature

Cooling is On

System operating mode

Fan operating mode (ap- pears when the fan is in continuous mode, disap- pears when it is in automat- ic mode)

p Press Clk to display the month.

q Set the month using

.

r Press Clk to display the date.

s Set the date using

.

t Press

 

to return to the normal display.

 

 

5.3 Fan Operating Mode

Press the Fan button to select the fan operating mode.

In automatic mode, the fan runs only when heating or cooling is activated. NOTE: For gas-operated HVAC systems, there might be a delay before the fan starts or stops when heating is acti- vated or deactivated.

In continuous mode, the fan runs continuously and the sym- bol is displayed. NOTE: if Smart Fan is enabled, when the con- troller is in periods 2 and 4 of automatic mode and in unoccupied mode, the fan will run only when heating or cooling is activated. The fan will run continuously the rest of the time

The controller normally displays the measured indoor temperature. To view the setpoint, press one of the buttons. The setpoint and the symbol will be displayed for the next 5 seconds.

6.2 System Operating Mode

Press Mode to place the system in one of the following modes:

HEAT The system is in heating mode.

COOL The system is in cooling mode.

The system is in automatic changeover mode. (The system

AUTO switches between heating mode and cooling mode to main- tain the desired temperature.)

OFF The system is off.

The system is in emergency heat mode. Only auxiliary heat-

EHEAT ing is used when there is a call for heat. (This mode applies only when the controller is connected to a heat pump

equipped with auxiliary heating).

TH146-P-2H1C

400-280-014-A

5/23/07

9/11

Page 9
Image 9
Aube Technologies TH146-P-2H1C manual General Setting, Temperature Setting

TH146-P-2H1C specifications

Aube Technologies, a renowned leader in temperature control and energy management solutions, has developed the TH146-P-2H1C model, a programmable thermostat designed to enhance user comfort and streamline energy consumption. This advanced thermostat is particularly acclaimed for its versatility and intelligent features, making it an ideal choice for both residential and commercial applications.

One of the main features of the TH146-P-2H1C is its ability to control heating systems efficiently. It supports various heating types, including electric baseboards, fan-forced heaters, and conventional heating systems, making it a flexible option for different environments. The thermostat offers simple programming options, allowing users to set specific temperatures for different times of the day and days of the week. This level of customization helps to optimize energy usage, leading to potential cost savings on heating bills.

In terms of technology, the TH146-P-2H1C incorporates an intuitive interface with a large, easy-to-read display. The user-friendly design facilitates straightforward programming and real-time temperature monitoring. It utilizes advanced temperature sensors to ensure accurate readings, adapting to the home or building’s unique heating needs. The thermostat also features a "hold" function, which allows users to maintain a specific temperature for an extended period, providing increased flexibility during unexpected schedule changes.

Another key characteristic of the TH146-P-2H1C is its energy-saving capabilities. It includes a built-in energy monitoring feature, enabling users to track their energy consumption over time. This transparency empowers homeowners and facility managers to make informed decisions about their heating practices, further promoting energy efficiency. The device also complies with modern energy standards, making it an environmentally friendly choice.

Security is another aspect that Aube Technologies emphasizes with this model. The TH146-P-2H1C includes a locking feature that prevents tampering, ensuring consistent settings and preventing unauthorized adjustments, which is particularly important in commercial settings.

Overall, the Aube Technologies TH146-P-2H1C thermostat represents a blend of functionality, energy efficiency, and user-friendly design. With its robust features and commitment to precise temperature control, it stands out as a compelling choice for those looking to enhance their heating systems while contributing to energy conservation efforts. Whether for personal residences or commercial spaces, the TH146-P-2H1C is poised to deliver comfort and reliability.