DEFINING YOUR PROGRAMS
1- This switch can memorize 2 “ON/OFF” programs which repeat themselves every day.
If you have entered your city’s parameters, the programs “P1 ON” and “P2 OFF” represent sundown and sunrise hours. Our example shows these results.
If your switch is set at “AUTO”, your lights will go on at sundown and go off at sunrise.
2- If you wish your lights to go on at sundown but go off for example at 23:00, enter program “P1 OFF - 23:00”.
Furthermore, if you wish your lights to go back on at 5:00 AM and go off at sunrise, enter program “P2 ON - 5:00”
nor | - Standard time |
| - Winter time |
|
|
Ad | - |
| - Summer time |
|
|
Note that the “P1 OFF” and “P2 OFF” programs have priority on the “P1 ON” and “P2 ON” programs respectively.
If, for example, the sun rises at 4:58 (“P2 OFF”) and you request in “P2 ON” that the lights go on at 5:00, the lights will not go on that morning.
3- If you wish to replace the “sundown” and/or “sunrise” programs by a fixed hour, select the “P1 ON” or “P2 OFF” programs and enter new parameters using the HOUR and MIN buttons.
SAVING YOUR PROGRAMS
1- Press on the PGM button to select the program.
2- Use the HOUR and MIN buttons to modify the program. 3- Press on the CODE button to return to the initial value.
P1 | ON = Sundown | P1 | OFF = |
P2 | ON = | P2 | OFF = Sunrise |
4- Press on the SAVE button to record your modifications and return to the MANUAL or AUTOMATIC operating mode.
TO SWITCH FROM STANDARD TIME TO
DAYLIGHT-SAVING TIME
If your country uses
1- Press 4 times on the CODE button to select the “nor/Ad” mode.
2- Use the MIN button to switch from the “nor” (Standard) mode to the “Ad”
3- Press on the SAVE button to return to the MANUAL or AUTOMATIC operating mode.
The programmable switch will automatically adjust the clock and the sundown/sunrise table for the period of the year. You do not need to adjust the clock manually.
MEMORY PROTECTION
The programmable switch is equipped with a rechargeable battery that will protect your program recordings during a power failure.
Note that the screen is not ON during power outage.
CHARACTERISTICS
Model: | ||
Supply: | 240 VCA, 50 / 60 Hz | |
Load: | 15 watts min., 500 watts max. | |
Approvals : | CE |
|
Storage temperature range: | ||
Operating temperature range: | 0 to 50 *C | |
Max. latitude : |
| +/- 65° |
Precision of the solar table: | +/- 11 min. (max. error near the Poles) |
| LAT | LONG |
GREECE | 39 | 22 |
ATHENS | 37 | 23 |
WARRANTY
AUBE TECHNOLOGIES INC. ONE YEAR LIMITED WARRANTY
This product is warranted against material defects and workmanship in normal use for a period of one year, from the date of the original pur- chase from authorized dealers. Warranty does not cover transportation costs. Nor does it cover a product subjected to misuse or accidental damage.
This limited warranty is in lieu of all other warranties, obligations or lia- bilities expressed or implied by the company.
In no event shall AUBE Technologies inc. be liable for consequential or incidental damages resulting from installation of this product. Within this period, any product proven defective in normal use will be repaired or replaced, at AUBE's option, without charge for either parts or labour, provided that the defective product with the original sale receipt is returned to the original dealer or is shipped
Head Office:
Aube technologies inc. |
|
705, Montrichard | 10 rue Ampère |
Iberville (Quebec) | 95500 Gonesse |
Canada J2X 5K8 | France |
Tel.: (450) | Tel.: 33 (0) 1 34 07 99 06 |
Fax: (450) | Fax: 33 (0) 1 34 07 99 19 |
www.aubetech.com | www.aubetech.com |
service@aubetech.com | advaube@comintes.com |
Carrer Segur, 74
08035 Barcelona
España
Tel.: 34 93 420 28 73
Fax: 34 93 429 30 79
www.aubetech.com