PROGRAMMABLE THREE-WAY SWITCH MODEL TI054A-06-3W

FOR ALL LIGHTING SYSTEMS

MAXIMUM CHARGE MUST NOT EXCEED 500 W / 230 V

The TI054A-06-3W three-way switch MAY be installed on EITHER of the following lighting systems:

-Incandescent

-Halogen

-Low voltage halogen with transformer

-Fluorescent

It must not be installed on a motor or a charge exceeding 500 W.

INSTALLATION

This programmable switch may be used in either a single pole or a mul- tiple pole switch installation.

Multiple pole switch installations with an electronic switch are different from conventional installations. Read the wiring instructions carefully and select the one that applies to your situation.

You must follow the steps in the indicated order at all times:

Note: Please note that the two (2) “C” terminals on the programmable switch have no polarity. They can both be used indiscriminately.

1.Cut the power supply at the main circuit breaker in order to avoid the risk of electrical shock.

2.Remove and disconnect all existing three-way or regular switches. In the case of a three-way switch, identify the wire connected to the “C” or “common” terminal.

3.Connect each wire, as it is disconnected, to the programmable switch following the appropriate wiring diagram.

4.Close the main circuit breaker to reinstate the power supply.

FOR A SINGLE POLE INSTALLATION

For a single pole installation no wire is connected to terminal “1”.

FOR AN EXISTING THREE-WAY SWITCH INSTALLATION

To replace a conventional three-way switch by a programmable one, follow the following wiring diagram:

The “common” wire (phase) that you identified while removing the existing three-way switch must be connected to one of the two “C” ter- minals on the programmable switch. Connect the other two wires (black) to the remaining two terminals on the programmable switch. The connecting wire supplied will be added to the remote three-way switch between the “common” terminal and the black wire connected to terminal “C” on the programmable switch. Once the connection is com- pleted, correctly install the switches in their own electrical box and close the main circuit breaker to reinstate the power supply.

FUNCTION CHECK

Refer to the “START-UP” section to start the programmable switch. Try to activate the lighting using the remote switch and the programmable switch. If everything is in working order, the installation is complete. Otherwise, cut the power supply at the main circuit breaker and recon- nect the connecting wire on the remote switch between the “common” terminal and the other terminal.

FOR A NEW THREE-WAY INSTALLATION

For a new installation, you may use a single pole switch at the remote location. Use the following wiring diagram:

Note: Note that the connecting wire supplied is not used in this installation.

START-UP

For the first trial under power, use a paper clip to push on the R button. You should see the figures 0:00 flashing on the screen.

If nothing appears on the screen, check the following points:

a)The programmable switch fuse may not be installed properly or may be defective.

b)If the programmable switch controls a lamp with its own switch, make sure that the latter is always “ON”.