ATW-CHG2 Features
•Batteries are charged within the transmitters.
•Versatile unit charges
•
•Automatic
•Automatic
•Maintenance charging prevents battery
•Includes
How to charge
1. Connect the power cord.
2.Set the transmitter’s power switch to the off position.
(Note:The transmitter’s power is automatically turned off if the transmitter is set in the charger with its power switch on; in this case, the transmitter will resume operation when it is removed from the charger.)
3.Install the
4.Insert the transmitter into the charger with transmitter charging contacts facing toward the charger’s contact pins.
5.Power is supplied to the charging bay when the transmitter is set into the unit; at this point the red indicator of each port lights.
(Note: If the red indicator does not light, poor contact may be the cause; set the transmitter in the charger again.)
6.When the charge is completed, the red indicator is turned off.
(Note: Maximum charging time is about ten hours.)
7.The unit keeps charging with
LED Status Indication
Charger indicator | Charging | Transmitter |
status | status | status |
Off | Power off | Transmitter not in unit |
|
|
|
Red light | Charging* | Transmitter in unit |
|
|
|
Red flashing | Charging error | Transmitter in unit |
| (Charging is stopped) |
|
|
|
|
Off | Charging is finished | Transmitter in unit |
| (Still maintenance charging) |
|
|
|
|
Note: Red flashing light (charging error) is caused by use of alkaline
*Note: If a transmitter with fully charged batteries is placed in the charger, the red light will remain on for a minimum of 3 hours, even though the batteries are fully charged.
Specifications*
Input Rating | 12V DC, 320 mA (maximum) |
Output Rating | 3.2V DC, 320 mA x2 |
|
|
Charging Time | Approx. 10 hours (2000 mAh |
Operating | 0~+40º C |
Temperature |
|
|
|
Dimensions | Approx. 131.0 mm (5.16") W x |
| 130.0 mm (5.12") D x 105.0 mm (4.13") H |
Weight | Approx. 40 g (1.4 oz) |
*Specifications are subject to change without notice.