REAR PANEL:

REAR PANEL:

3. BUS Line Inputs / Outputs

The AMP1200 has two common or BUS inputs that

receives audio signals from standard line-level audioCLOSE UP OF CONNECTIONS sources and sends them to any or all channels. The BUS

line outputs are direct feed-through to allow the BUS inputs to be fed to other amplifiers. Be sure to use high quality RCA cables that feature low impedance, shielding and high quality connectors.

4. Remote Turn-On Switch

This switch selects the turn-on stimuli that will put the ampli -

voltage going into the trigger input to activate the amplifier. “Auto” setting senses a signal on the RCA line-level inputs and automatically puts the amp in ready mode.“On” setting puts the amp constantly in ready mode so that it can be controlled by the master power switch on the front panel.

minutes to return from ready to standby mode.

5.Trigger Input / Output

The trigger input is a handy feature when connecting the

plug jack will accept a 3-30V AC/DC output from another

 

 

 

 

device, or from a separate power supply. When the trigger

 

 

 

 

input is energized, the amp turns from standby to ON mode.

 

 

 

 

When using the AMP1200 with a receiver without a trigger

 

 

 

 

output, the voltage can come from a 12V wall wart (3.5mm

 

 

 

 

tip-positive connector) plugged into the receiver’s switched

 

 

 

 

outlet and the trigger input.The AMP1200 can also provide

9. Speaker Output Terminals

 

an output trigger voltage (12DC @500mA max.) to turn on

The AMP1200 uses high quality Phoenix style connectors

 

and off other devices in the audio system.When the ampli

-

for the speaker connections. Use 14-18 gauge stranded

 

 

 

two-conductor loudspeaker wire. Ensure that at least

 

Note : Remember there is a delay of approximately 15

2 inches of each conductor are separated. Strip away

 

¼ inch of insulation from each conductor. Connect the

 

minutes before the amplifier goes to standby when using

 

appropriate conductor to each screw terminal, observing

 

the “Auto” turn-on mode.

 

 

 

correct polarity. Also, please observe proper speaker wir

-

 

 

6. Channel Gain Control

 

ing when bridging channels.

 

Each channel has its own independent level adjustment.

 

10. Individual Channel Input

 

This allows the output level of each speaker to be per

-

 

All twelve channels have their own dedicated input that

 

fectly matched to its area. It can also be used to limit the

 

 

 

allows the connection of audio sources in addition to

 

maximum audio level in a certain area.

 

 

 

the common BUS inputs. This is useful when using the

 

 

 

 

7. Bridging Switch

 

AMP1200 with an audio matrix switcher.

 

combined to increase the total power output.This is helpful

11. AC Voltage Switch

 

The unit is set at the factory for 115V U.S.operation;simply

 

when extra power is needed in certain areas.

 

 

 

connect the included IEC power cord to your wall outlet.

 

 

 

 

Note: The minimum impedance for bridged channels is 8

For 230V operation, move the voltage selector switch to the

 

ohms.Also, please observe the proper speaker wiring when

230V position. When operating at 230V the internal fuse

 

bridging channels. Input selection and volume settings for

located in the IEC socket should also be changed. In most

 

bridged channels will be controlled by the left channel.“BR”

230V applications a separate power cord will be required

 

is bridged mode and “ST” is non-bridged or stereo mode.

and is not included.

 

CAUTION: Only change switch positions when the

 

12. IEC Power Connector

 

amplifier is turned off.

 

The unit comes with an IEC jack that permits removal of

 

8. Input Selection Switch

 

-

 

 

ing the power cord for different countries. The IEC

 

Each channel is capable of delivering the source from

 

 

 

socket also houses the main fuse holder. Plug the power

 

many inputs. The three main inputs are BUS 1, BUS 2

 

 

 

cord supplied with the amplifier into the amplifier and a

 

and LINE IN. The selection for these inputs is done via

 

 

 

wall outlet or appropriate surge protector.

 

the Input Selection switch associated with each channel.

 

 

 

CAUTION: DO NOT plug the amplifier’s power cord into

 

Select the desired source input. Set the Input Selection

 

 

switch to BUS 1 (will play source connected to the BUS

 

a switched outlet, such as what is provided on some Sur

-

1 input), BUS 2 (will play source connected to the BUS

 

round Receivers. If you wish to have the amplifier turn on

 

2 input) or LINE IN (will play source connected to that

 

when the Receiver is powered up, use one of the power

 

channel’s LINE IN).

 

modes, such as Trigger or Auto.

 

CAUTION: Only change switch positions when the amplifier is turned off.