INSTALLATION
The unit can be installed horizontally, vertically or at a 45° angle. The position of the
CAUTION
After setting the
HORIZONTAL INSTALLATION Set the 2
VERTICAL INSTALLAITON Set the 2
45° ANGLE INSTALLATION
Set the 2
ANTI-VIBRATION SPRINGS POSITION
PROCEDURE FOR HORIZONTAL INSTALLATION W/O STUDS
1
Attach a bracket to each side of the unit, using the machine screws with integral flat and lock washers (M4 x 10).
In the horizontal position, use bracket mounting holes 1 and 1' as shown at the right.
Set
NOTE: Use masking tape to cover un- used mounting holes on sides of unit.
1
2
3
1
2
3
MACHINE SCREW WITH FLAT AND LOCK WASHERS (M4 x 10)
2
Determine unit mounting location, and drill four mounting holes.
Never mount the unit near the fuel tank.
DRILL HOLES 4MM IN DIAMETER
3
Secure the unit in place, using four
Use RTV (silicone sealer) on screw threads and around the holes to prevent moisture intrusion.
BRACKET (Left Side)
BRACKET (Right Side)
4