Audiovox VOD705 owner manual Troubleshooting, Negative Switched Dome lighting, Symptomremedy

Models: VOD705

1 11
Download 11 pages 43.42 Kb
Page 10
Image 10
Negative Switched Dome lighting

Negative Switched Dome lighting

To 12 pin

 

Red / black - Lamp on

 

connector

 

Black / red - Lamp common

 

 

Purple / brown - Lamp Auto

 

 

 

 

 

 

 

 

 

on Monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

To

constant

+12vdc

Factory Dome light circuit

To

constant

+12vdc

Factory Door ajar switch or Body Control computer

Troubleshooting:

SYMPTOM:REMEDY:

No power at Video Monitor -Verify +12 VDC on Red wire at 2 pin Power Harness behind video monitor. Verify ground connection with continuity test from known good ground to black wire at 2 pin Power Harness

Power but no video or sound

Picture, but no sound

-Verify that the correct source is selected (i.e.:1,2,3 or 4). Verify that the source is on and playing a known good media (such as a DVD or video- tape). Verify connections at both ends of the source component harness.

-Push and hold the volume up button () on the remote control until sound is heard over wired headphones. If problem is limited to the dash radio, verify radio is tuned to the correct frequency, and that power to the wired RF modulator is on. Otherwise, verify all connections per the wiring dia- gram on page 6 .

No Infrared remote func- tions for VCP (or other com- ponents)

-Check batteries in the hand held remote. Verify that the IR LED ( page 6 Wiring Diagram) is properly attached to the sensor window of the VCP (or other component).

-8-

Page 10
Image 10