Negative Switched Dome Lighting

Negative Switched Dome Lighting

To 12 pin

 

 

Red / black - Lamp on

 

 

 

 

 

 

 

 

 

 

Black / red - Lamp common

 

 

 

 

 

 

 

 

connector

 

Purple / brown - Lamp Auto

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To

constant

To

constant

Factory Door ajar switch or Body Control computer

Troubleshooting:

SYMPTOM:

REMEDY:

No power at Video Monitor

Verify +12 VDC on Red wire at 2 pin Power Harness

 

behind video monitor. Verify ground connection with

 

continuity test from known good ground to black wire at 2

 

pin Power Harness

Power but no video or sound

Verify that the correct source is selected (i.e.: 1,2,3 or 4).

 

Verify that the source is on and playing a known good

 

media (such as a videotape). Verify connections at both

 

ends of the source component harness.

Static on TV Stations

Press Auto Program button. Then press CH up or CH

(Tuner Version Only)

down. Verifyantenna mounting and connections to the

 

tuner.

 

Note: Due to the nature of TV signals, vehicle motion,

 

direction the vehicle is facing, distance from the

 

transmitter, nearby surroundings and weather may

 

adversely affect TV reception. These conditions may

 

result in the following: picture roll, "snowy" picture, or

 

momentary loss of color.

No Infrared remote functions

Check batteries in the hand held remote. Verify that the IR

for VCP (or other components)

LED (page 9 Wiring Diagram) is properly attached to the

 

sensor window of the VCP (or other component).