Safety Precautions
IF YOU SMELL GAS:
*Do not light any appliance
*Extinguish any open flame
*Do not touch any electrical switch or plug or unplug anything
*Open windows and vacate building
*Call gas supplier from neighbor's house, if not reached, call fire department
This unit must be installed by a qualified installer to prevent the possibility of an explosion. Your dealer will know the requirements in your area and can inform you of those people considered qualified. The room heater should be inspected and cleaned before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
The instructions in this manual must be strictly adhered to. Do not use makeshift methods or compromise in the installation. Improper installation will void the warranty and safety listing.
This heater is either approved for natural gas (NG) or for propane (LP). Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard. Direct questions about the type of fuel used to your dealer. Check for a label on the flame adjust knob on the gas control valve (this is the best place to check). You may also check for a label on the gas control valve body.
Contact your local building |
| If the flame becomes sooty, dark |
officials to obtain a permit and |
| orange in color, or extremely tall, |
information on any installation |
| do not operate the heater. Call |
restrictions or inspection |
| your dealer and arrange for |
requirements in your area. |
| proper servicing. |
Notify your insurance company |
|
|
of this heater as well. |
|
|
It is imperative that control | ? | Do not operate the heater if it is |
compartments, screens, or | not operating properly in any | |
circulating air passageways of | fashion or if you are uncertain. | |
the heater be kept clean and | Call your dealer for a full | |
free of obstructions. These | explanation of your heater and | |
areas provide the air necessary | what to expect. | |
for safe operation. |
| |
|
| Do not operate if any portion of |
Do not store or use gasoline or |
| the heater was submerged in |
| water or if any corrosion occurs. | |
other flammable liquids in the |
| |
| Immediately call a qualified | |
vicinity of this heater. |
| |
| service technician to inspect the | |
|
| |
|
| appliance and to replace any part |
|
| of the control system and any |
|
| gas control that has been under |
|
| water. |
© Travis Industries | 4081205 |