3-Wire Power Cord Installation
Cut Ground Strap
Terminal Block Neutral Wire Power Wires Power Cord
Bracket

3-Wire Power Cord Installation

Remove the Terminal Block Access Plate on the back

 

of range by removing the 2 fixing screws.

Screws

Assemble the strain relief in the hole on bracket.

 

Insert the power cord through the strain relief and

 

tighten.

 

Allow enough slack to easily attach the cord terminals

 

to the terminal block.

 

Remove the 3 wire terminal nuts and washers from

Terminal Block

the terminal block.

Access Plate

Plug the terminal holes of power cord. The neutral or

ground wire of the power cord must be connected to the neutral terminal located in the center of terminal block. The power leads must be connected to the outside terminals.

Plug washers and tighten nuts securely.

Assemble the Terminal Block Access Plate.

4-Wire Power Cord Installation

Remove the Terminal Block Access Plate on the back

of range by removing the 2 fixing screws.

Cut Ground Strap

Grounding Screw

Assemble the strain relief in the hole on bracket.

Terminal Block

 

Insert the power cord through the strain relief and

Neutral Wire

 

 

 

tighten.

Grounding Wire

 

Allow enough slack to easily attach the cord terminals

Power Wires

 

to the terminal block.

Power Cord

 

Remove the 3 wire terminal nuts and washers from

 

Bracket

 

the terminal block.

 

 

 

Remove the ground strap from the frame of range and terminal by removing its screw and cutting is as shown.

Plug the terminal holes of power cord. The neutral wire of the power cord must be connected to the neutral terminal located in the center of terminal block. The ground wire of the power supply cord must be attached to the frame of range by using the green colored grounding screw. The power leads must be connected to the outside terminals.

Plug washers and tighten nuts securely.

Assemble the Terminal Block Access Plate.

LEVELING THE RANGE

The range must be level to obtain proper operating. The four screws type leveling legs located on the corners at the bottom of range should be adjusted by turning them clockwise to make the range higher or counter-clockwise to lower the range until the range is level. Use a level on surface units to check the leveling of the range.