Installation Procedures for Dual Radio Modules Installing the MDW 9040 Pocket Phone System
MDW Wireless Pocket Phone Installation and Use,
503-801-190 Issue 2,February 2001 17
To install multiple radio modules for single zone operation:
1 Remove each radio module from its shipping box and place it in the location you
have selected (for wall-mounting instructions, see “Wall-Mounting the Dual
Radio Module” on page 14).
2 For the first handset to be connected to the radio module, connect a 14 foot
(4.2 m) Station Line Cord (provided) to Line 1 on the radio module and then
connect the other end of the cord to a station port at the main system. If a second
handset is to be connected to the radio module, connect another Station Line Cord
to Line 2 on the radio module and then connect the other end of that cord to
another station port.
Note: If the radio module cannot be connected to an associated switch, the radio
module can be temporarily connected to an auxiliary power supply that
can provide electrical power.
3 Verify that the radio module has power and that the status LED information is
correct. See “Dual Radio Module Light Indications” on page 10.
4 Repeat Steps 1 and 2 for each radio module and handset combination in this
configuration.
5 To daisy chain two or more radio modules, plug the 20 inch (50 cm)
synchronization cable (provided) from the Sync jack on one radio module to the
Sync jack on the other radio module (either Sync jack can be used).
6 Proceed to “Setting Up and Registering the Handset” on page 35.
Installing Multiple Radio Modules in a Dual Zone Configuration
Dual zone coverage allows you to originate and receive calls using the same handset for two radio modules in
either Zone 1 or Zone 2. Dual zone installations require two station ports, one for each radio module, as shown in
Figure 6 below.
Figure 6. Dual Zone Installation
Radio Module 1 Radio Module 2
Dual Zone
Switch
Station Port 1 Station Port 2