2.7.2 Connector Electrical Characteristics

Item

Test Condition

Requirements

Contact Resistance

ANSI/EIA-364-23

20mΩ, maximum, initial per

 

 

contact mated pair

 

 

10mΩ, maximum change from

 

 

original per contact mated pair

Shell Resistance

ANSI/EIA-364-06A-83

50mΩ, maximum initial

 

Contact resistance measured from

50mΩ, maximum change from

 

receptacle shell leg to plug cable

original

 

braid. Test current = 100mA; Test

 

 

Voltage = 5V DC open circuit

 

 

maximum

 

Dielectric Withstanding Voltage

ANSI/EIA-364-20

No Flash-over, No Spark-over, No

 

Test voltage 500V DC ± 50V

Excess Leakage, No Breakdown

 

Method C, unmated and

 

 

un-mounted Barometric pressure

 

 

of 15 psi

 

Insulation Resistance

ANSI/EIA-364-21

1GΩ minimum between adjacent

 

Test voltage 500V DC ± 50V

contacts and contacts and shell

 

Method C, unmated and

 

 

un-mounted

 

Contact Current Rating

ANSI/EIA-364-70, TP-70

1.5A minimum

 

55°C, maximum ambient

 

 

85°C, maximum temperature

 

 

change

 

Applied Voltage Rating

 

40V AC(ms) continuous maximum,

 

 

on any signal pin with respect to

 

 

the shield

Electrostatic Discharge

IEC 801-2

No evidence of discharge to

 

Test un-mounted from 1kV to 8kV

contacts. Discharge to the shell is

 

in 1kV steps using 8mm ball probe

acceptable.