www.avenview.com
7
2.2 Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
Power Supply
VCC
-0.3
5.5
V
Operating Temperature
VOT
0
50
°C
Storage Temperature
VST
-20
70
°C
Relative Humidity
HRH
10
80
RH
2.3 Signal Pin Assignment
Transmitter / Receiver
Pin
Pin
Signal Assignment
1
11
T.M.D.S Clock Shield
2
12
T.M.D.S Clock -
3
13
CEC
4
14
No Connect
5
15
SCL
6
16
DSA
7
17
DDC/CEC Ground
8
18
+5V Power
9
19
Hot Plug Detect
10
Stresses greater than those listed under “Absolute Maximum Ratings” may cause
permanent damage to the device. This is a stress rating only and functional operation of
the device at these or any other conditions above those indicated in the operations section
for extended periods of time may affect reliability.