The following is a summary of all operational commands.

Key Sequence

Action

<CTRL><CTRL>Addr<Enter>

Selects an active channel via keyboard.

<CTRL><CTRL>Dnn<Enter>

Configures the dwell time. Substitute nn with

 

a value from 2 to 60 seconds.

 

 

<CTRL><CTRL>SG<Enter>

Enables the scan Go command.

 

 

<CTRL><CTRL>SH<Enter>

Enables the scan Halt command.

 

 

<CTRL><CTRL>M+<Enter>

Mouse will suspend scanning.

 

 

<CTRL><CTRL>M-<Enter>

Mouse will not suspend scanning. (default)

 

 

<CTRL><CTRL>MR<Enter>

If you hot-plug the SwitchView to a PC con-

 

nection you may experience a loss of mouse

 

signal. Use this command to restore the signal

 

if you’re using a PC with a standard PS/2

 

mouse driver. (See page 8)

 

 

<CTRL><CTRL>MW<Enter>

Use this command to restore the mouse signal

 

if you’re using a PC with a Microsoft Intel-

 

liMouse driver. (See page 8)

 

 

<CTRL><CTRL>Kn<Enter>

Sets keyboard scan set; n is a number 1 - 3.

 

 

<CTRL><CTRL>AV<Enter>

Displays the current firmware version of the

 

SwitchView processors. You must be at a DOS

 

prompt or in a text editor/word processor to

 

view this information.

 

 

<CTRL><CTRL>H1<Enter>

Default Command Mode Activation

 

 

<CTRL><CTRL>H2<Enter>

Changes the Command mode activation

 

sequence to <ALT> <ALT>

 

 

<CTRL><CTRL>H3<Enter>

Changes the Command mode activation

 

sequence to <Shift> <Shift>

 

 

<CTRL><CTRL>H4<Enter>

Changes the Command mode activation

 

sequence to <NUMLOCK> <->

 

 

<CTRL><CTRL>ZM<Enter>

Used to resynchronize the mouse after a hot-

 

plug. Repeat, if necessary, until synchroniza-

 

tion is re-established.

 

NOTE: Using this command while the mouse

 

is operating correctly will cause the mouse

 

to lose sync.

 

 

10