1.2 RS-232 Device Cabling
Figures 3 through 5 show the pin assignments required for an RS-232 cable connection between the ESP RJ-45 ports and your devices.
To ESP | Pin # |
| Pin # | To Terminal / Printer |
Clear to Send | 10 |
| 4 | Request to Send |
N/C | 9 |
|
|
|
N/C | 8 |
|
|
|
Signal Ground | 7 |
| 7 | Signal Ground |
Transmit Data | 6 |
| 3 | Receive Data |
Receive Data | 5 | . | 2 | Transmit Data |
Data Carrier Detect | 4 | 20 | Data Terminal Ready | |
N/C | 3 | 8 | Data Carrier Detect | |
DataTerminal Ready | 2 | 6 | Data Set Ready | |
Request to Send | 1 | 5 | Clear to Send | |
|
|
| ..... o o o o o o o . 1 | |
|
|
| ..... o | |
1 |
|
|
| |
.......... |
|
| 1 | |
|
|
| ............ |
|
|
Cable End View | Cable End View |
Figure 3. Cable Pin Assignments for ESP RJ-45 to Terminal/Printer
To ESP | Pin # |
| Pin # | To PC | |
Clear to Send | 10 |
| 7 | Request to Send | |
N/C | 9 |
|
|
|
|
N/C | 8 |
|
|
|
|
Signal Ground | 7 |
| 5 | Signal Ground | |
Transmit Data | 6 |
| 2 | Receive Data | |
Receive Data | 5 | . | 3 | Transmit Data | |
Data Carrier Detect | 4 | 4 | Data Terminal Ready | ||
N/C | 3 | 6 | Data Set Ready | ||
Data Terminal Ready | 2 | 1 | Data Carrier Detect | ||
Request to Send | 1 | 8 | Clear to Send | ||
1 |
|
|
| o o o o o | 1 |
.......... |
|
|
| ||
|
|
|
| ||
|
|
|
| o o o o |
|
|
|
| |||
Cable End View |
|
|
| Cable End View |
Figure 4. Cable Pin Assignments for ESP RJ-45 to PC DB-9
To ESP | Pin # | Pin # | To Modem |
Clear To Send | 10 | 5 | Clear to Send |
N/C | 9 |
|
|
N/C | 8 |
|
|
Signal Ground | 7 | 7 | Signal Ground |
Transmit Data | 6 | 2 | Transmit Data |
Receive Data | 5 | 3 | Receive Data |
Data Carrier Detect | 4 | 8 | Data Carrier Detect |
N/C | 3 |
|
|
Data Terminal Ready | 2 | 20 | Data Terminal Ready |
Request to Send | 1 | 4 | Request to Send |
.......... 1 |
| 1 | |
|
| ............ | |
|
| ||
Cable End View |
|
| Cable End View |
Figure 5. Cable Pin Assignments for ESP RJ-45 to Modem DB-25
5Equinox ESP