(0.78 in), Axis part number: 38118, manufacturers:
Rayovac, Panasonic, Renata.)
– Users shall not replace the battery. If the battery needs
replacing, a factory trained service professional shall
contact Axis support at www.axis.com/techsup for
assistance.
– Used batteries shall be disposed of according to local
laws and regulations, which may vary from state to state.
Waste BR lithium cells are neither listed nor exempted
from the USEPA hazardous waste regulations. Waste BR
lithium batteries can be considered reactive hazardous
waste if there is a significant amount of unreacted, or
unconsumed lithium remaining. For information about
how to dispose of used lithium batteries, contact your
local authority for waste disposal.
Specifications
• Operating Conditions
– Temperatures beyond 0 °C to 49 °C (32 °F to 120 °F) has
not been verified as part of UL 294.
• Wire Area
– UL Listed or R/C AWM wires that have an conductor
gauge range of AWG 22–14 shall be used.
– The minimum conductor gauge for connection between
the power sourcing equipment (PSE) or power injector
and the powered device (PD) is 26 AWG.
• Connectors
– This product is not intended for outside wiring as covered
by Article 800 in the National Electrical Code, NFPA 70.
– Power Connector – For UL security applications, the
product shall be powered by a UL 294 Listed or UL 603
Listed Class 2 low-voltage power limited power supply
that is capable of 4 hours of standby power.
– Network Connector – Power over Ethernet (PoE) shall be
supplied by a UL 294 Listed Class 2 power limited injector
that provides 44–57 V DC, 15.4 W and 4 hours of standby
power. Compliance with IEEE 802.3 (at or af)
specifications has not been verified as part of UL 294/B.
– Tampering Alarm Pin Header – To comply with UL
294/7.2.1 (Enclosure), the tampering alarm shall be
connected to a sound alarm.
• System Considerations
– The Axis product, whether it is a standalone door
controller or a system of door controllers, shall not impair
the intended operation of the panic hardware used in
conjunction with it.
• Wall and Ceiling Mount
– If using a junction box to mount the Axis product, the
junction box shall be UL Listed.
• Assign an IP Address
– The functionality of AXIS Camera Management, see page
36, has not been evaluated by UL.
• Maintenance Instructions
– For maintenance instructions (some steps require access
to the product’s webpages), see page 40. For information
about how to configure the Axis product using the
product’s webpages (AXIS Entry Manager), see the User
Manual.
English

System Considerations

The Axis product shall be installed within the secured area.
The Axis product, whether it is a standalone door controller
or a system of door controllers, shall not limit or waken the
intended use of the devices connected to it.
The Axis product should be installed on a wall (preferred) or a
ceiling, with or without a junction box. It can also be
installed on a DIN rail.

Safety Information

Read through this Installation Guide carefully before
installing the product. Keep the Installation
Guide for future reference.
Hazard Levels
Read through this Installation Guide carefully before
installing the Axis product. Keep the Installation Guide for
further reference.
Indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
Indicates a situation which, if not avoided, could result in
damage to property.
Other Message Levels
Indicates significant information which is essential for the
product to function correctly.
Indicates useful information which helps in getting the most
out of the product.

Safety Instructions

The Axis product shall be installed by a trained professional.
• Never mount the Axis product while power is applied to the
product. Always apply power at the end of the installation.
• Disconnect power before connecting any wires to the Axis
product. Never make connections while power is applied to
the product..
• The Axis product shall be used in compliance with local
laws and regulations.
• To use the Axis product outdoors, or in similar
environments, it shall be installed in an approved outdoor
housing.
• Store the Axis product in a dry and ventilated environment.
• Avoid exposing the Axis product to vibration, shocks or
heavy pressure.
• Do not install the product on unstable brackets, surfaces or
walls.
• Use only applicable tools when installing the Axis product.
Excessive force could cause damage to the product.
• Do not use chemicals, caustic agents, or aerosol cleaners.
Use a damp cloth for cleaning.
• Use only accessories that comply with technical