Axis Communications user manual Axis P1344-E Network Camera

Models: P1344-E

1 59
Download 59 pages 27.91 Kb
Page 50
Image 50

AXIS P1344-E Network Camera

System Options

2.Press and hold the Control button and reconnect power (see Hardware overview, on page 5 ).

3.Keep the Control button pressed for about 15 seconds until the Status indicator flashes amber.

4.Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The product has been reset to the factory default settings. The default IP address is 192.168.0.90

5.Re-assign the IP address.

6.Refocus the product.

It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.

50

Page 50
Image 50
Axis Communications user manual Axis P1344-E Network Camera