AXIS P5512-E PTZ Dome Network Camera

System Options

Note

To prevent corruption of recordings, the SD card should always be unmounted before removal.

If the card’s status shows as failed, click Check disk to see if the problem can be found and then try Repair.

The settings under Storage Device Settings are used to configure removal of recorded video. Automatic disk cleanup can be enabled and set according to a schedule. The disk can be locked to prevent removal of recordings.

For more information, see the online help.

Network Share

Network share allows you to add network storage such as a NAS (Network Attached Storage) or any server that uses CIFS (Common Internet File System) and use them for storage of recordings.

To add a network share:

1.Go to System Options > Storage.

2.Click Network Share.

3.Enter the IP address, DNS or Bonjour name to the host server in the Host field.

4.Enter the name of the share in the Share field. Sub folders cannot be used.

5.If required, select The share requires login and enter the user name and password.

6.Click Connect.

To clear all recordings and data from the Axis product’s folder on the designated share, click Clear under Storage Tools.

To avoid filling the share, it is recommended to remove recordings continuously. Under Recording Settings, select Remove recordings older than and select the number of days or weeks.

To stop writing to the share and protect recordings from being removed, select Lock under Recording Settings.

Maintenance

The Axis product provides several maintenance functions. These are available under System Options > Maintenance.

Click Restart to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current settings.

Click Restore to reset most settings to the factory default values. The following settings are not affected:

the boot protocol (DHCP or static)

the static IP address

the default router

the subnet mask

the system time

the IEEE 802.1X settings

uploaded applications are kept but must be restarted

Click Default to reset all settings, including the IP address, to the factory default values. This button should be used with caution. The Axis product can also be reset to factory default using the control button, see Reset to Factory Default Settings, on page 46.

To test the product’s PTZ mechanics, click Test under PTZ Status.

44

Page 44
Image 44
Axis Communications P5512 user manual Maintenance, Go to System Options Storage Click Network Share