Install the network camera

!IMPORTANT!

The supplied RJ45 connector or a compatible, IP66 rated RJ45 connector must be used in order to comply with the IP66 rated design of the camera.

1.Install the selected bracket (not included) according to the instructions supplied with the bracket. If drilling is required, make sure to use drill bits, screws, and plugs that are appropriate for the material. See www.axis.com for infor- mation on available mounting accessories.

2.Route the network cable and attach the supplied RJ45 connector. Refer to the instructions provided with the connector for information on wiring and assembly.

3.Hook the camera to the safety wire on the bracket.

 

 

Torx T30

 

 

Screws

Safety

 

Slots for

 

wire

 

unit holders

Wall bracket (mounting example, bracket not included)

ENGLISH

4.Connect the network cable and RJ45 connector to the network connector on the camera.

5.Install AXIS T8123, see Install AXIS T8123 High PoE Midspan 1-port,on page 10.

6.Check that the indicator LEDs on the midspan indicate the correct conditions, see the table on page 11 for further details.

7.Slide the unit holders on the camera into the slots on the bracket and rotate the camera unit.

8.Secure the network camera to the mounting bracket by fastening the 3 screws (Torx T30).