Axor 38030XX1 installation instructions Re-setthe high temperature limit stop optional

Models: 38030XX1

1 8
Download 8 pages 13.39 Kb
Page 4
Image 4
Re-set the high temperature limit stop (optional)

Re-set the high temperature limit stop (optional)

This step should be taken if the faucet is to be used by small children or others who should be protected from scalding.

Pull out the screw cover, located on the bottom of the handle.

Use a 3 mm allen wrench to loosen the set screw 2 complete turns.

Pull off the nut cover and the green high temperature limit stop ring.

Reinstall the high temperature limit stop ring so that the black positioning pin is in the notch corresponding to the desired high temperature. The temperatures shown in the diagram assume an incoming cold water temperature of 50oF and an incoming hot water temperature of 140o.

Center and replace the nut cover.

Replace the handle.

Tighten the set screw.

4

Page 4
Image 4
Axor 38030XX1 installation instructions Re-setthe high temperature limit stop optional

FAQ

Why should I re-set the high temperature limit stop?

This step should be taken if the faucet is to be used by small children or others who should be protected from scalding.

What tools do I need to re-set the high temperature limit stop?

You will need a 3 mm allen wrench to loosen the set screw.

What temperatures are assumed in the diagram?

The temperatures shown in the diagram assume an incoming cold water temperature of 50oF and an incoming hot water temperature of 140o.