Quick Start Guide

Quick Start Guide

ESR901WB Wireless 802.11b

Serial Server

Model: ESR901WB

1 Configure Web Access

‰Infrastructure Mode

Configure your network using an access point with the SSID - Connect and all encryption disabled (such as WEP & WPA). ‰Wireless Card Ad-Hoc Mode

Configure the wireless card to operate in Ad-Hoc mode with the SSID - Connect.

2

Setup the Hardware

‰Connect your PC to the wireless network

 

‰Connect the antenna to the ESR901WB

 

‰Connect 10 VDC to 30 VDC to the power supply

 

terminals of the ESR901WB

 

‰Connect the ESR901WB serial port to the serial

 

port of your serial device. (Use a null cable if the

 

serial device is a DTE.)

 

3

Power it up

 

‰Apply power to the ESR901WB

 

‰The Link LED (yellow) will blink while looking for the

 

wireless network. When a connection is established with

 

the network the Link LED will illuminate steadily. The

 

ESR901WB will connect to the SSID Connect. If it cannot

 

find an SSID of connect it will connect to the first

 

unsecured network it finds.

 

‰The ESR901WB will automatically try to obtain an IP

 

address though DHCP, or generate one itself

 

 

4

Get the IP Address

 

‰Use the discovery software on your CD (finder.exe)

 

to get the IP address for your ESR901WB

 

‰If necessary, change the IP address using the

 

discovery software

Documentation Model Number ESR901WB-2907qs PN6871-rev002

5 Logiinn

‰In a web browser on your PC, type in the IP address and access the Web Configuration and Management Interface

‰Login using the username ‘root’ and password ‘dbps’

6 Connffiigguurree tthhee EESSRR990011WWBB

‰In the Configuration, Network page configure your Wireless LAN, Security and other settings to work on the type of wireless network you will be connecting to.

‰In the Configuration, Serial Ports page select the Port Profile you require for use with your application (E.g. RealPort for virtual COM port, TCP Server, UDP server, Serial Bridge, etc)

‰Configure the serial port settings for the selected Port Profile (E.g. In TCP Sockets select client or server, TCP port numbers, etc.) Also configure baud rate, data bits, etc in Basic Serial Settings.

‰Configure any required alarms and notification ‰If RealPort profile was selected (virtual COM

port) do the next step (Set up VCOM)

7

Set uupp VVCCOOMM

 

‰Start the RealPort software wizard (located on the

 

included CD)

 

‰Select Add a New Device

 

‰Select your ESR901WB from the list

 

‰Select an unused COM port number

 

‰Follow the wizard to set up a virtual COM port

8 Operraattiioonn

‰Configure and then start your application

 

International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA

 

815-433-5100 Fax 433-5104www.bb-elec.com orders@bb-elec.com support@bb-elec.com

Documentation Model Number ESR901WB-2907qs PN6871-rev002

European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland

+353 91 792444 Fax +353 91 792445 www.bb-europe.com orders@bb-europe.comsupport@bb-europe.com

Page 1
Image 1
B&B Electronics quick start Quick Start Guide, Model ESR901WB, Configure Web Access, Setup the Hardware, Power it up