OIL BURNER COMBUSTION TESTING KIT ORDERING INFORMATION

ITEM

KIT

 

STANDARD KIT

 

 

EXPORT KIT*

 

NO.

CONTENTS

10-5014

10-5002

10-5022

10-5036

10-5050

10-5150

10-5023

10-5037

10-5051

10-5064

Fire Efficiency Finder

■

■

■

■

■

■

 

 

 

10-0100

Carrying Case (large)

■

 

■

■

■

■

■

■

■

11-0121

Moisture Absorb. Material

■

■

■

■

■

■

■

■

■

11-7029

Sampling Hose Assembly

■

■

■

■

■

■

■

■

■

11-7032

Fyrite CO2 20%-Filled

■

■

■

■

■

 

 

 

 

12-7014

Tempoint Therm. 1000° (6” Stem)

■

■

■

■

 

■

 

 

 

13-7019

MZF Draft, +.05 to -.25”W

■

 

■

 

 

■

 

 

 

10-0099

Carrying Case (small)

 

■

 

 

 

 

 

 

 

13-3000

Draftrite, +.10 to -.14”W

 

■

 

■

 

 

 

 

 

21-7006

True Spot Smoke Tester

 

 

■

■

■

■

■

■

■

12-7018

Tempoint Therm. 1000° (12” Stem)

 

 

 

 

■

 

 

 

 

13-7021

MZF Draft, +.05 to -1.0”W

 

 

 

 

■

 

 

 

 

10-5175

Stack Loss Calculator

 

 

 

 

 

 

■

■

■

11-7031

Fyrite CO2 20%-Unfilled

 

 

 

 

 

■

■

■

■

12-7015

Tempoint Therm. 540°C (6” Stem)

 

 

 

 

 

 

■

■

 

13-7020

MZF Draft, +1.0 to -2.5mmW

 

 

 

 

 

 

■

 

■

13-7018

MZF Draft, +1.0 to -5mmW

 

 

 

 

 

 

 

■

 

12-7017

Tempoint Therm. 540°C (12” Stem)

 

 

 

 

 

 

 

 

■

*Export Kits are similar to standard kits except Fyrite Indicators are shipped without fluid installed. Draftrite, MZF Draft Gauge,

Manometer and Tempoint are supplied metric in most instances. Fluid for export kits must be purchased separately in three bottle cartons.

GAS BURNER COMBUSTION TESTING KIT ORDERING INFORMATION

ITEM

KIT

STANDARD KIT

 

EXPORT KIT*

 

NO.

CONTENTS

 

10-5030

10-5035

10-5217

10-8008

 

10-5047

 

10-5224

10-0070

GAS SERVICE CALCULATOR

■

■

■

 

 

 

 

■

10-5064

FIRE EFFICIENCY FINDER

■

■

■

 

 

 

 

■

10-5067

HIGH EFFICIENCY FINDER

■

■

■

 

 

 

 

 

10-0100

CARRYING CASE

■

■

■

■

 

■

 

■

11-0121

MOISTURE ABSORB. MATERIAL

■

■

■

■

 

■

 

■

11-7029

SAMPLING HOSE ASSEMBLY

■

■

 

 

 

■

 

■

11-7045

EXTENDED SAMPLING HOSE ASSEMBLY (10’)

 

 

 

■

 

 

 

 

11-7032

FYRITE CO2, 20% FILLED

■

■

■

 

 

 

 

 

11-7036

FYRITE O2, 21% FILLED

■

 

■

 

 

 

 

 

12-7014

TEMPOINT THERMOMETER 1000°F (6”STEM)

■

■

■

 

 

 

 

■

13-3000

DRAFTRITE +.10 TO .14”W

■

■

■

 

 

 

 

■

17-7002

MANOMETER 15”W 8.5OZ/IN 2

■

■

■

 

 

 

 

■

19-0003

SAMPLING TUBE ATTACHMENT

■

 

■

 

 

■

 

 

19-7021

CO DETECTOR KIT

■

 

 

 

 

■

 

 

11-7045

SAMPLING TUBE ASSEMBLY

 

 

■

■

 

 

 

■

19-0001

SPARE TUBE TIPS (6)

■

 

■

■

 

 

 

■

19-0243

MONOXOR INDICATOR .2%

 

 

■

■

 

 

 

■

19-5015

CARTON OF 12 CO TUBES

 

 

■

■

 

 

 

■

10-5175

STACK LOSS CALCULATOR

 

 

 

■

 

■

 

 

11-7031

FYRITE O2, 20% UNFILLED

 

 

 

■

 

■

 

■

11-7035

FYRITE O2, 21% UNFILLED

 

 

 

■

 

■

 

■

19-0242

MONOXOR INDICATOR .2%

 

 

 

 

 

 

 

 

19-5010

CARTON OF 12 CO TUBES

 

 

 

 

 

 

 

 

12-7015

TEMPOINT THERMOMETER 540°C (6”STEM)

 

 

 

■

 

■

 

 

13-3002

DRAFTRITE +2.5 TO -3.5MM W

 

 

 

 

 

■

 

 

17-7000

MANOMETER 15”W, 38CMW

 

 

 

■

 

■

 

 

13-3003

DRAFTRITE -6.5MM TO 1.5MM

 

 

 

■

 

 

 

 

19-7019

MONOXOR PUMP

■

 

 

 

 

 

 

 

19-5002

MONOXOR CO TUBES

■

 

 

 

 

 

 

 

Distributed By:

Fyrite, True Spot, Tempoint, Monoxor, Draftrite and Bacharach are registered trademarks of Bacharach, Inc. © 2003, Bacharach, Inc. All rights reserved. All information herein is subject to verification.

Product Bulletin-4171 08/03 10M DXC HPC Printed in U.S.A.

Headquarters: 621 Hunt Valley Circle, New Kensington, PA 15068 U.S.A.

Phone: 1-800-736-4666 Canada: 1-800-328-5217 E-Mail: help@bacharach-inc.com Website: www.bacharach-inc.com

Page 2
Image 2
Bacharach MZF Distributed By, OIL Burner Combustion Testing KIT Ordering Information, KIT Standard KIT Export KIT Contents

MZF specifications

Bacharach MZF is a sophisticated gas analyzer designed for the precise measurement and monitoring of combustion gases, offering advanced solutions for various industrial applications. With its high sensitivity and reliability, the MZF model stands out as an essential tool for maintenance and diagnostic tasks in combustion systems.

One of the main features of the Bacharach MZF is its capability to measure multiple gas components, including carbon monoxide (CO), carbon dioxide (CO2), oxygen (O2), and unburned hydrocarbons. This multi-gas analysis provides comprehensive insights into the combustion process, enabling users to assess efficiency, emissions, and potential safety hazards. The ability to simultaneously measure these gases allows for a quicker and more accurate evaluation of combustion performance.

The MZF utilizes cutting-edge technologies to ensure high accuracy and reliability. Its electrochemical sensors are specifically designed for prolonged use, providing stable and precise readings even in demanding environments. This reliability is complemented by its user-friendly interface, which includes an intuitive display that presents real-time data. Users can effortlessly navigate through different measurement modes and access historical data for trend analysis and reporting.

One outstanding characteristic of the Bacharach MZF is its portability. Weighing only a few pounds, this compact analyzer is designed for both field and shop applications, making it an ideal choice for technicians and professionals on the go. Its robust construction ensures that the analyzer can withstand tough working conditions, increasing its durability and lifespan.

Moreover, the MZF features advanced data logging capabilities, allowing users to store a substantial amount of measurement data. This functionality is crucial for long-term monitoring and compliance with environmental regulations, as it provides a clear record of performance over time. The analyzer can also connect to external devices for easy data transfer, facilitating reporting and analysis.

In conclusion, the Bacharach MZF embodies a blend of advanced technology, user-centric design, and robust functionality. Its ability to measure multiple gas components accurately makes it a valuable asset for professionals seeking to optimize combustion processes while ensuring safety and compliance with regulatory standards. As industries continue to prioritize efficient and clean combustion practices, tools like the Bacharach MZF will play a pivotal role in achieving these goals.