Bakers Pride Oven 400, 800, 600, 805, 100, 300, 125, 200 manual Models Covered, Receiving

Models: 200 125 300 100 400 805 600 800

1 12
Download 12 pages 23.8 Kb
Page 3
Image 3

For European Community Countries:

EN 437

Gases and Supply

Designated European Market = ￿

 

 

 

Gas Cat.

Pressures

A

B

D

F

F

G

D

I

I

L

N

P

E

S

G

 

 

T

E

K

I

R

R

E

E

T

U

L

T

S

E

B

I2H

G20 @ 20mbar

￿

 

￿

￿

 

 

 

￿

￿

 

 

￿

￿

￿

￿

I2L

G25 @ 25mbar

 

 

 

 

 

 

 

 

 

 

￿

 

 

 

 

I2E

G20 @ 20mbar

 

 

 

 

 

 

￿

 

 

￿

 

 

 

 

 

I2E+

G20/25 @ 20/25mbar

 

￿

 

 

￿

 

 

 

 

 

 

 

 

 

 

For North America:

Type of Gas

Manifold Pressure

Natural

3.5” Water Column

LP

10” Water Column

MODELS COVERED

MODEL

BTU/hr

kw

100 Series

48,000

14.06

200 Series

60,000

17.53

300 Series

70,000

20.50

400 Series

80,000

23.44

3151 Series

70,000

20.50

4151 Series

70,000

20.50

D-125

*125,000

*36.61

DS-805

70,000

20.50

GS-805

60,000

17.58

Y-600

120,000

35.15

Y-800

120,000

35.15

*Model D-125 is rated 105,000 BTS/hr (30.76 kw) for use with LP Gas. All other models have the same rating for Natural and LP Gas. LP Gas models are not available for European Community Countries.

I. INSTALLATION INSTRUCTIONS

1.RECEIVING:

Read the notice on the outside carton regarding damage in transit. Damage discovered after opening the crate(s)/carton(s) is ‘CONCEALED DAMAGE’ and the carrier must be notified immediately to send an inspector and also to furnish forms for the consignee’s claim.

When the oven arrives, it should consist of:

a)A crate or carton containing your new oven.

b)A carton containing 4 legs with mounting hardware.

c)A strapped skid containing baking decks.

Installation must conform with local codes and/or with the latest edition of the ANS Z-223.1 National Fuel Gas Code in USA ( CAN/CGA-B 149.1 or 2 Installation Code in Canada).

This appliance must be installed by a competent person in accordance with the rules in force. In the U.K. Corgi registered installers (including the regions of British Gas) undertake to work to safe and satisfactory standards. This appliance must be installed in accordance with the current Gas Safety (Installation and Use) Regulations and the relevant Building Regulations / IEE Regulations. Detailed recommendations are contained in the British Standard Codes Of Practice BS 6172, BS 5440:Part 2 and BS 6891.

Place the oven and parts as close as possible to the area of final installation before uncrating.

3

Page 3
Image 3
Bakers Pride Oven 400, 800, 600, 805, 100, 300, 125, 200 manual Models Covered, Receiving