Bakers Pride Oven BLF-FC Automatic Lift Fryer, Operation, Item #, Description, Function

Models: BLF-FC

1 32
Download 32 pages 5.2 Kb
Page 15
Image 15
Manual background

Automatic Lift Fryer

Operation

 

 

 

 

 

 

Item #

Description

Function

6

ALARM button

This button allows the user to set an elapsed time at which the

 

 

internal alarm will sound during a cycle. The time is set by

 

 

pressing and holding the ALARM button while using the UP and

 

 

DOWN arrows to change the time. The controller will limit the

 

 

alarm time to be less than the currently programmed interval cycle

 

 

time. The default alarm time is 0:00 which disables it. The ALARM

 

 

time is saved on power down in the same manner as the last

 

 

interval time. When a time cycle is running and the alarm time has

 

 

elapsed the internal alarm will sound for 10 seconds. For

 

 

example, a cycle time 10:00 and alarm time of 2:00 would cause

 

 

the alarm to sound for 10 seconds once the controller has counted

 

 

down from 10:00 to 8:00. This button is also used to cancel the

 

 

STIR OIL function.

 

A, B, C, D preset

These buttons are used to save and recall preset cycle and alarm

 

buttons

times, saving operator time and minimizing error when changing

 

 

interval cycle times and alarm times. To save the current interval

 

 

and alarm times into one of the preset locations, press and hold

 

 

the A, B, C, or D preset button for 2 seconds and the controller will

 

 

double chirp to indicate the times have been saved. To recall any

 

 

preset time, press and quickly release the appropriate button and

 

 

the time values are loaded and displayed.

 

Beeper

A beeper sounds when the timer counts down to 0. Pressing the

 

 

START/STOP button stops the beeper and resets the timer

 

 

causing the display to return to the original starting time. At this

 

 

point, time can be changed using the TIME SELECT buttons or

 

 

the preset buttons. The beeper will also sound for 10 seconds if

 

 

the alarm time has elapsed during a timing cycle. When the STIR

 

 

OIL function begins the beeper will sound until the ALARM or

 

 

START/STOP button is pressed.

 

Display

Used to display the time. It also displays the words “STIR” then

 

 

“OIL” in .5 second intervals until the ALARM or START/STOP

 

 

button is pressed.

7

High Limit Reset

Located under the control panel. If the heating elements inside the

 

Switch

pot reach an unsafe temperature, power is automatically removed

 

 

from the control panel, lift mechanism and elements. Pressing this

 

 

switch returns power to the control panel, lift mechanism and

 

 

elements.

8

Drain Lever

DRAIN OPEN – When placed in this position, the drain valve

 

 

opens and shortening in the pot drains into the vat. Also, power is

 

 

removed from the control panel, lift mechanism and elements.

 

 

DRAIN CLOSED – When placed in this position, the drain valve is

 

 

closed to prevent shortening from draining into the pot.

9

Fill Lever

FILL THRU POT – When placed in this position, shortening can

 

 

be pumped automatically from the vat to the pot if the rocker

 

 

switch is in the FILTER position.

 

 

FILL THRU HOSE – When placed in this position, shortening can

 

 

be pumped from the vat to the pot via a connected hose if the

 

 

rocker switch is in the FILTER position.

10

Rinse Hose Connector

Used to connect the Rinse hose for cleaning and refilling the pot.

11

Pump Motor Reset

If the motor overheats while filtering, it will automatically shut off.

 

Switch

Wait 15 minutes to allow motor to cool before pressing this switch.

13

Page 15
Image 15
Bakers Pride Oven BLF-FC operation manual Automatic Lift Fryer, Operation, Item #, Description, Function