Electric Pressure Fryer |
| Operation | |
|
|
|
|
|
|
|
|
STEP | ACTION | DISPLAY | COMMENTS |
12 | Press TOGGLE/CLEAR until the | PROGRAM VALVE1 | X refers to the solenoid |
| desired option is displayed. | X | valve option selected. |
|
|
| OPEN is used for Models |
|
|
| ALF and BLF Automatic |
|
|
| Lift fryers. If your program |
|
|
| requires the solenoid valve |
|
|
| to be closed while |
|
|
| cooking, choose the |
|
|
| CLOSED option. |
13 | Repeat steps |
| The time and temperature |
| programming stages 2, 3, 4 and |
| of each stage has to be |
| 5 for Electric and Gas appliance |
| less than the preceding |
| types. |
| stage. |
| Repeat steps |
|
|
| programming stages 2, 3, 4 and |
|
|
| 5 for an ALF appliance type. |
|
|
14 | Press ENTER. | PROGRAM PREALARM | This command allows you |
|
| 00:00 | to specify the number of |
|
|
| minutes before the end of |
|
|
| the cooking time (for each |
|
|
| stage) until the alarm |
|
|
| sound The prealarm value |
|
|
| displayed may be a |
|
|
| previously programmed |
|
|
| value. |
15 | Press TOGGLE/CLEAR and | PROGRAM PREALARM | XX:XX refers to the |
| input the prealarm minutes. | XX:XX | prealarm minutes you |
|
|
| input. |
16 | Press ENTER. | PROGRAM FILTER | This command allows you |
|
| 0 | to specify the number of |
|
|
| fry cycles you want to |
|
|
| complete for this program |
|
|
| before a message is |
|
|
| displayed reminding you to |
|
|
| filter the shortening (filter |
|
|
| lockout). The filter value |
|
|
| displayed may be a |
|
|
| previously programmed |
|
|
| value. |
17 | Press TOGGLE/CLEAR and | PROGRAM FILTER | X refers to the number of |
| input the number of fry cycles | X | program cycles you want |
| you want to complete before |
| to complete before filtering |
| enabling filter lockout. |
| the shortening. |
18 | Press ENTER. | PROGRAM PRODUCT # |
|
19 | If you wish to input more |
|
|
| programs, proceed by pressing |
|
|
| the next program number and |
|
|
| follow steps 5 through 18 or |
|
|
| press PROG to exit the |
|
|
| programming mode. |
|
|
20