SureCross™ DX81 FlexPower™ Supply Module

Delivers and manages dc voltage from one 3.6V dc lithium primary battery

Features

Wireless solution for powering a FlexPower™ Node and sensor device

Unique power management system to run the FlexPower Node and a device through switched power outputs for up to five years, depending upon the power requirements of the device

Replaceable 3.6V dc Lithium “D” cell battery

IP67 sealed enclosure

FlexPower systems allow for a true wireless solution as the Node can be powered by battery power (3.6 to 5.5V dc). Battery life is application specific. Contact Banner Engineering’s application engineers for a battery life calculation for your specific application.

For additional information and a complete list of replacement parts, please refer to Banner Engineering’s website, www.bannerengineering.com/surecross.

Models

Model

Power

Batteries

Cable

 

 

 

 

DX81

3.6V dc Battery

One 3.6V Lithium “D” Cell

5-pin Euro Pigtail QD

 

 

 

 

Battery Replacement

Battery Replacement

To replace the lithium “D” cell battery in the DX81 FlexPower™ battery kit,

1.Remove the four screws mounting the battery pack face plate to the body.

2.Remove the face plate.

3.Remove the discharged battery and replace with a new battery. Verify the battery’s positive and negative terminals align to the positive and negative terminals of the battery holder mounted within the case. Caution: Risk of explosion of battery is replaced with an incorrect type.

4.After replacing the battery, allow up to 60 seconds for the device to power up.

When removing the battery, press the battery towards the negative terminal to compress the spring. Pry up on the battery’s positive end to remove from the battery holder. Properly dispose of your used battery according to local regulations by taking it to a hazardous waste collection site, an e-waste disposal center, or any other facility qualified to accept lithium batteries.

As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or expose them to high temperatures. Do not recharge, crush, disassemble, or expose the contents to water.

WARNING… Not to be used for personnel protection

Never use these products for personnel protection. Doing so could lead to serious injury or death.

These products do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A failure or malfunction can cause either an energized or de-energized product output condition. Consult your current Banner Safety Products catalog for safety products that meet OSHA, ANSI, and IEC standards for personnel protection.

Printed in USA

11/07

P/N 131596 rev. C