Banner manual SureCross DX81P6 FlexPower Supply Module, Battery Replacement, Hookup Diagram

Models: DX81P6

1 4
Download 4 pages 63.01 Kb
Page 2
Image 2
SureCross™ DX81P6 FlexPower™ Supply Module

SureCross™ DX81P6 FlexPower™ Supply Module

Battery Replacement

Battery Replacement

To replace the lithium “D” cell battery pack in the DX81P6 FlexPower™ battery kit,

1.Remove the four screws mounting the clear plastic battery pack cover to the housing.

2.Remove the cover and foam spacer.

3.Disconnect the discharged battery pack.

4.Remove the discharged battery pack and replace with a new battery pack. Caution: There is an explosion risk if the battery pack is replaced with an incorrect type.

5.After replacing the battery pack, allow up to 60 seconds for the device to power up.

Properly dispose of the used battery packs according to local regulations by taking it to a hazardous waste collection site, an e-waste disposal center, or any other facility qualified to accept lithium batteries.

As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or expose them to high temperatures. Do not recharge, crush, disassemble, or expose the contents to water.

Replacement battery pack model number: BWA-BATT-002. For pricing and availability, contact Banner Engineering.

Hookup Diagram

5-pin M12 Quick Disconnect Pinout

Only SureCross™ FlexPower™ DX80 devices may be powered from this supply.

3

Blue

dc common (GND)

5

Gray

3.6 to 5.5V dc

 

 

 

Banner Engineering Corp. • Minneapolis, MN U.S.A

 

      P/N 131628 rev. B

www.bannerengineering.com • Tel: 763.544.3164

 

 

Page 2
Image 2
Banner SureCross DX81P6 FlexPower Supply Module, Battery Replacement, Hookup Diagram, pin M12 Quick Disconnect Pinout