uDo not connect the laminator to electrical power or attempt to operate it until you have read these instructions completely. Keep these instructions in a convenient location for future reference.

uRead all safety messages located in this instruction manual and on the laminator very care- fully.

uAlways replace safety shield before operating your laminator. If you service this machine yourself, ensure that the safety shield is returned to the operating position when service is completed. Do this to protect all operators. Operators may be harmed if you do not follow this instruction.

uRemoving feed table exposes hot and moving parts. This means that you can be harmed if you remove the feed table. When the table is in the proper position the risk of injury to the operator is reduced.

uDo not operate this laminator without all detachable units installed correctly. This means that there is risk of injury if this product is operated without all of its parts in their proper positions.

uKeep hands and clothing away from rollers. The rollers are pinch points that can trap body parts or clothing and cause serious injury.

uDo not touch the front rollers while the laminator heater power is on. Turn rollers off and allow to cool.

uDo not use the laminator for other than its intended purpose.

uOnly operate this machine if you have been properly trained and authorized to do so. Contact the manufacturer for training information at 909-296-9780.

II.Electrical Safeguards...

uNever override or attempt to defeat electrical or mechanical safety interlock devices.

uDisconnect power supply before servicing your laminator. This laminator uses double pole/neutral fusing.

uA readily accessible disconnect device should be incorporated in the fixed wiring.

uThe machine has been manufactured without a plug on the power cord. We recommend that you connect this unit directly to a power main. Have a qualified electrician install your power supply for you. Care must be exercised to properly identify the neutral wire in the power cord. The neutral power cord wire is color coded white. The neutral of the power main should be identified using a suitable voltmeter.

uThe laminator should only be operated from the type of power source indicated in these OPERATING INSTRUCTIONS and on the serial label located on the rear panel of the unit.

uDo not leave the laminator power on for extended periods while not in use. Open the panel breaker at the end of the day as a precaution against a possible fire hazard.

2

Page 5
Image 5
Banner American Products BA-EN45 manual For your safety, II. Electrical Safeguards

BA-EN45 specifications

Banner American Products has long been a leader in the manufacturing of innovative and effective solutions for various industrial needs. One of their standout products is the BA-EN45, a versatile and efficient equipment designed for a variety of applications. This article delves into the main features, technologies, and characteristics of the BA-EN45, giving readers a clear understanding of its benefits.

The BA-EN45 is built with a robust design, ensuring durability and long-term performance in challenging environments. Its reinforced structure provides resistance to impacts and harsh conditions, making it ideal for industrial settings where reliability is paramount. The compact design also allows for easy integration into existing systems and workflows, enhancing productivity without requiring significant alterations to current setups.

One of the defining features of the BA-EN45 is its advanced sensing technology. Equipped with state-of-the-art sensors, it offers high precision and responsiveness. This technology enables accurate detection and monitoring, reducing the likelihood of errors and increasing operational efficiency. The intelligent sensing capabilities are particularly beneficial in automated processes, where timely information is crucial for optimal performance.

In addition to its sensing technology, the BA-EN45 boasts a user-friendly interface. Its intuitive controls and display options ensure that operators can easily navigate functions and settings, facilitating quick adjustments and enhancing usability. The product also supports various connectivity options, allowing integration with other systems and real-time data sharing, which is essential for modern industrial ecosystems.

Another notable characteristic of the BA-EN45 is its energy efficiency. Designed with sustainability in mind, it minimizes energy consumption without compromising performance. This attribute not only reduces operational costs but also aligns with the growing emphasis on environmentally friendly practices within industries.

Furthermore, the BA-EN45 is backed by rigorous testing and quality assurance processes, ensuring that each unit meets the highest standards of performance and reliability. Its long lifespan and low maintenance requirements make it a cost-effective choice for businesses looking to enhance their operational capabilities without substantial investment in ongoing upkeep.

In conclusion, the Banner American Products BA-EN45 is a cutting-edge solution that combines durability, advanced technology, and user-friendly design. Its impressive features make it an excellent choice for various industrial applications, positioning it as a valuable asset for organizations aiming to improve efficiency and reliability in their operations.