9. Service Mode
Proj 1 Proj 2 Proj 3 Proj 4
in in in in
out out out
RS RS RS
Terminator
Image9-7
Principaldiagram : linkingvia RS port
Linking via the Comm port
Theconstant light output of the projectors can be s etto the same value by linking the projectors via the Comm port and using one
or more Comm 800 splitters (See Connections, Linked System).
To slave 1
Master Projector
Comm port
Comm 800 splitter
To slave 2
To slave 3
To next Comm 800 splitter
"To Switcher"
To slave 4
Comm 800 splitter
To slave 5
To slave 6
To slave 7 or to
next Comm 800 splitte
r
"To Switcher"
Image9-8
Principaldiagram: Linked via Comm port
Formore information about the use of the Comm 800 splitter, consult the Comm 800 splitter documentation (R5976819).
Which information is available
serialnumber unique serial number of the lamp
type lamp type
run time totaltime the lamp is used in this or other pro jectors.
remainingrun time timeleft before the lamp must be replaced Using the lamp longer than the maximum run time may
damage the projector.
numberof strikes Totaltimes the lamp is started up.
Z-AXIS indication to adjust the Z-AXIS of the lamp (see Re-adjustment of the lamp position in chapter
Installation Guidelines).
R5976801 SLM R9+ 20/10/2004 111