9. Service Mode
Entering the necessary addresses.
1. Select the IP address with the cursor keys. (menu 9-24)
2. Press ENTER to edit.
3. Enter or reprogram th eaddress with the numeric keys (conta ctyour netwo rk responsiblef or the correct address).
Anaddress c ontains 4 octets with a maximum value of 255, separated by a bullet.
4. Repeat the above steps for the subnet mask and the defaultgateway.
5. Select APPLY and press ENTER to install the entered addresses.
If a wrong value for an octet is entered, the following error message will be displayed to indicate where the error is located.
Exampleof message : "Invalidoctet. Themaximum value is 255 for each octet ! " . (menu9-25)
NETWORK CONFIGURATION
DHCP [ON]
IP ADDRESS 158.150.160.200
SUBNET MASK 158.150.160.201
DEFAULT GATEWAY
158.150.300.300
MAC ADDRESS 01:01:02:DB:FF:89
APPLY
Select with or
<ENTER> to edit
Reprogram with or
or numeric keys
APPLY to confirm
<EXIT> to return
Menu9-24
ERROR
Invalid octet
the maximum value is
255 for each octet!
<EXIT> to return.
Menu9-25
9.9 Lamp
Lamp information light output switching
All information about the lamp is stored inside the lamp house andcan be displayed via the projector software on the projection
screen. No information can be changed.
TheCo nstant light output function can be changed between OFF,[slave] and [master].
By using the CLO function, the lamp life time will enlarge.
CLO for a single projector
Whenthe CL O functionsis in the OFF position, the lamp will follow the normal life cycle curve.
Whenthe CLO function is ON (projector master or slave), the projector will regulate the lamp power until the preprogrammed CLO
value (number of lumens) (full line) isreached. As long as this power is below the maximum power of the lamp, the projector will
givesa constant light output. Oncethe maximum power is reached, the projector will follow again the normal lamp life cycle curve.
R5976801 SLMR9+ 20/10/2004 109