SERVICE

SERVICE HINTS

1.Caution homeowner to maintain clean air filters at all times. Also, not to needlessly close off supply and return air registers. This reduces air flow through the system, which shortens equipment service life, as well as, increasing operating costs.

2.Check all power fuses or circuit breakers to be sure that they are the correct rating.

3.Periodic cleaning of the outdoor coil to permit full and unrestricted air flow circulation is essential.

FAN BLADE SETTING DIMENSIONS

Shown in Figure 10 are the correct fan blade setting dimensions for proper air delivery across the outdoor coil.

Any service work requiring removal or adjustment in the fan and/or motor area will require that the dimensions below be checked and blade adjusted in or out on the motor shaft accordingly.

FIGURE 10

FAN BLADE

C

B

A

 

 

 

7960-337

 

TABLE 12

 

 

FAN BLADE SETTING

 

 

 

 

Model

Dimension A

 

Fan Hub Locations

 

 

 

 

HAC181

 

 

 

HAC241

5"

 

B

HAC301

 

 

 

 

HAC361

 

 

 

 

 

 

 

HAC421

 

 

 

HAC481

4-3/4"

 

C

HAC601

 

 

 

 

 

 

 