Bard WL484, WL423, WL602 Recommended Airflow, Maximum ESP of Operation Electric Heat only

Models: WL423 WL602 WL484

1 20
Download 20 pages 38.09 Kb
Page 19
Image 19

TABLE 8

RECOMMENDED AIRFLOW

 

Rated

Rated

Recommended

Model

CFM *

ESP *

Airflow Range

 

 

 

 

WL423

1400

.30

1600 - 1150

WL484

1550

.20

1750 - 1285

 

 

 

 

WL602

1700

.30

1950 - 1375

* Rated CFM and ESP on high speed tap.

TABLE 9

MAXIMUM ESP OF OPERATION

ELECTRIC HEAT ONLY

Model

WL423

WL484

WL602

 

High

Low

High

Low

High

Low

KW

Speed

Speed

Speed

Speed

Speed

Speed

-A05

.50

.50

.50

.50

.50

.50

-A10

.50

.50

.50

.50

.50

.50

-A15

.50

.50

.50

.50

.50

.50

-B00

.50

.50

.50

.50

.50

.50

-B09

.50

.50

.50

.50

.50

.50

-B15

.50

.50

.50

.50

.50

.50

-C09

.50

.50

.50

.50

.50

.50

-C15

.50

.50

.50

.50

.50

.50

Values shown are for units equipped with standard 1 inch throwaway filter or 1 inch washable filter. Derate ESP by .15 for 2 inch pleated filters.

TABLE 10

PRESSURE TABLE

COOLING

 

 

 

Air Temperature Entering Outdoor Coil °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return Air

 

 

 

 

 

 

 

 

 

 

 

Model

Temperature

Pressure

75

80

85

90

95

100

105

110

115

 

 

75 deg. DB

Low Side

70

72

73

75

76

77

78

79

79

 

 

62 deg. WB

High Side

207

220

235

251

266

283

300

318

337

 

WL423

80 deg. DB

Low Side

75

77

78

80

81

82

83

84

85

 

67 deg. WB

High Side

212

226

241

257

273

290

308

326

346

 

 

 

 

85 deg. DB

Low Side

78

80

81

83

84

85

86

87

88

 

 

72 deg. WB

High Side

219

234

249

266

283

300

319

337

358

 

 

75 deg. DB

Low Side

73

74

76

78

79

80

82

83

84

 

 

62 deg. WB

High Side

204

217

232

248

265

284

304

325

348

 

WL484

80 deg. DB

Low Side

78

79

81

82

84

86

87

89

90

 

67 deg. WB

High Side

210

223

238

254

272

291

312

334

357

 

 

 

 

85 deg. DB

Low Side

84

85

87

88

90

92

93

95

97

 

 

72 deg. WB

High Side

217

231

247

264

282

302

323

345

369

 

 

75 deg. DB

Low Side

71

72

74

75

76

77

78

78

79

 

 

62 deg. WB

High Side

233

247

262

278

295

313

331

351

371

 

WL602

80 deg. DB

Low Side

76

78

79

80

81

82

83

84

85

 

67 deg. WB

High Side

237

253

269

285

303

321

340

390

381

 

 

 

 

85 deg. DB

Low Side

84

85

85

86

87

88

89

90

91

 

 

72 deg. WB

High Side

245

261

278

296

314

333

353

373

394

Low side pressure ± 2 PSIG

High side pressure ± 5 PSIG

Tables are based upon rated CFM (airflow) across the evaporator coil. If there is any doubt as to correct operating charge being in the system, the charge should be removed, system evacuated and recharged to serial plate instructions.

NOTE: Pressure table based on high speed condenser fan operation. If condensing pressures appear elevated check condenser fan wiring. See “Condenser Fan Operation” on Page 14.

Manual 2100-400

Page 17

Page 19
Image 19
Bard WL484, WL423, WL602 Recommended Airflow, Maximum ESP of Operation Electric Heat only, Pressure Table Cooling

WL423, WL602, WL484 specifications

Bard WL484, WL602, and WL423 are part of Bard's innovative line of heating, ventilation, and air conditioning (HVAC) products designed to meet the diverse needs of residential and commercial spaces. Each model is characterized by advanced technologies that enhance energy efficiency, performance, and user comfort.

The Bard WL484 model showcases a heating capacity of 48,000 BTU and operates efficiently in various environments. This unit incorporates a robust heat exchanger, which allows for rapid heating without sacrificing efficiency. One of the standout features of the WL484 is its integrated control system that allows users to set precise temperatures, enhancing comfort while minimizing energy usage. Additionally, this model is designed with superior airflow capabilities, providing even temperature distribution throughout the space it serves.

The Bard WL602, with a heating capacity of 60,000 BTU, emphasizes versatility and performance. This unit is equipped with a multi-speed blower that adjusts the airflow according to the specific heating requirements of the environment. The WL602 is engineered with a durable cabinet that resists corrosion, ensuring longevity and reduced maintenance needs. It also includes advanced diagnostic capabilities, allowing users to identify issues quickly and streamline servicing. With its enhanced efficiency ratings, the WL602 is a solid choice for larger spaces requiring reliable and economic heating solutions.

The Bard WL423 model serves as an efficient option for smaller spaces with a heating capacity of 24,000 BTU. This compact unit is designed to fit into tighter spaces while delivering exceptional performance. One unique characteristic of the WL423 is its quiet operation, making it suitable for environments where noise levels must be kept to a minimum, such as offices or bedrooms. Additionally, it features energy-efficient components that help reduce operating costs over time, making it an attractive option for budget-conscious consumers.

In summary, Bard WL484, WL602, and WL423 each bring distinct advantages to the HVAC market, with features designed for optimal performance, energy efficiency, and user satisfaction. These models represent Bard's commitment to quality and innovation, ensuring that customers can find the right solution for their specific heating needs. Whether for residential or commercial applications, Bard continues to be a trusted name in climate control technology.