2 SPECIFICATIONS GENERAL

Transmission Rate:

1200 Baud (Bell 202 signaling) or V.23 if factory installed

Transmission Format:

8 data bits, no parity, 1 stop bit if modem buffering is selected;

 

otherwise transparent

Power Requirement:

Operates from 12 to 30 VDC. Current drain is 110 mA with the LEDs on,

 

65 mA with the LEDs off.

Temperature Range:

-30oC to +50oC

Physical Size:

Approx. 10" x 5" x 1", inside a metal enclosure

Radio and Wireline:

Compression screw terminals located inside the enclosure

Data Connector:

RS232-C compatible, connections available through a DB-25S socket

 

located on the side of the enclosure

Indicators:

Power ON, TXD, RXD, CD, RTS, CTS, BUSY

Receive Audio:

Single ended, AC coupled, -30 dBm to 0 dBm

Transmit Audio:

Single ended, AC coupled, -20 dBm to 0 dBm

Squelch Detection:

Single ended, 1M ohm impedance, DC coupled, detection range

 

0 to 10 volts, polarity is DIP switch selectable

PTT:

Closure to ground for active, 0.5 A @ 50 volts max.

4 Wire Receive:

Balanced, 600 ohm impedance, -30 dBm to 0 dBm (operates full or

 

half duplex)

4 Wire Transmit:

Balanced, 600 ohm impedance, -20 dBm to 0 dBm (operates full or

 

half duplex)

DIP SWITCH SETTINGS

Transmitter Level:

-20 dBm to 0 dBm

Receiver Level:

-30 dBm to 0 dBm

Squelch Polarity:

Selects high or low going squelch monitor signals.

Carrier Detect Delay:

5 or 50 msec

Assert RTS:

Forces RTS on.

RTS/CTS Delay:

20, 35, 50, 100, 200, 300, 500, or 1000 msec. Allows the transmitter

 

time to reach full power before data is transmitted.

B1474

BARNETT ENGINEERING LTD.

PAGE 5

Page 6
Image 6
Barnett Engineering B1474 operation manual Specifications General, DIP Switch Settings