Baxi Potterton G.C.No 47 393 20, G.C.No 47 393 18 warranty Troubleshooting, Boiler not working

Models: G.C.No 47 393 19 G.C.No 47 393 20 G.C.No 47 393 18

1 12
Download 12 pages 3.33 Kb
Page 4
Image 4
Boiler not working

Boiler not working

START

Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker).

NO

If no gas, consult your supplier.

2.0 Troubleshooting

YES

Is the ON/OFF/Reset

YES

Is the (

) or (

) light on

NO

 

Select Switch in the

 

and the (

) on ?

 

 

 

 

 

 

 

 

 

(

) position and

Central Heating

 

 

 

 

 

the display lit ?

 

 

 

Domestic Hot

 

Indicator

 

 

 

 

 

 

 

 

 

Water Indicator

 

 

 

 

 

 

 

Reset

 

 

 

Burner On

 

 

YES

Indicator

 

 

 

NO

 

Display

 

 

 

 

 

 

Boiler operating satisfactorily.

Check electricity to the

 

 

boiler is switched on.

 

 

Is the Central Heating System

YES

Pressure needle in the GREEN

 

 

section, between 1 and 2.5 bar ?

 

Does the display show an error

NO

code e.g. E133, E110 ?

 

 

NO

2

13 2.0 Troubleshooting

04

bar

If the reading falls below 1 bar repressurise the system as described in section 3.1.

YES

Turn the ON/OFF/Reset Selector Switch to Reset.

Reset

If boiler does not Reset

Error Code E119 showing low pressure.

4© Baxi Heating UK Ltd 2012

Page 4
Image 4
Baxi Potterton G.C.No 47 393 20, G.C.No 47 393 18, G.C.No 47 393 19 warranty Troubleshooting, Boiler not working