BEA 10PBS45X, 10PBR45X, 10PBDGP1 Precautions, Pre Installation Check, Hardwire Bracket - Optional

Models: 10EMSQ475X 10PBDGP1 10PBR45X 10PBS45X

1 4
Download 4 pages 53.68 Kb
Page 2
Image 2
3Precautions

3Precautions

Shut off all power before attempting any wiring procedures.

Maintain a clean & safe environment when working in public areas.

Constantly be aware of pedestrian traffic around the door area.

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.

Always check placement of all wiring before powering up to insure moving door parts will not catch any wires and cause damage to equipment.

Ensure compliance with all applicable safety standards (i.e. ANSI A156.19 / A156.10) upon completion of installation.

DO NOT attempt any internal repair of the sensor. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair:

1.May jeopardize personal safety and may expose one to the risk of electrical shock.

2.May adversely affect the safe and reliable performance of the product resulting in a voided warranty.

4Pre Installation Check

1.When preparing to wire multiple devices together for a ‘system’ configuration, it is best to ensure the correct operation of each device independently before starting to help reduce troubleshooting time later in the event of a discrepancy.

2.Prior to installing any equipment, ensure correct line voltage and stability. When applying equipment on a new installation utilizing new electrical supply circuits, always ensure correct line voltage exists and is stable. Remember to shut the power back off after this is checked and before performing any wiring to the system.

5 Installation

1

Hardwire Bracket - Optional

FOR HARDWIRING RUN WIRE THROUGH 1” DIAMETER HOLE

1.55in

39.37mm

 

1.00 in

 

25.40 mm

 

0.44 in

 

11.11 mm

 

2.12 in

 

53.95 mm

3.65 in

2.19 in

92.71 mm

 

55.58 mm

5.65in

143.51mm

1/4-20

3.55in

92.10mm

1.The Bollard is designed to house a pushplate used to activate a door by either a remote controlled transmitter or hardwired directly to the door control. If the door is hardwired, pass the wire through the 1 inch diameter hole in the mounting bracket.

2

Attach Mounting Bracket Using Expansion Anchors - Existing Concrete

1.Mark and drill 3/8” diameter hole in four locations.

2.Hammer in and set anchor in four hole locations.

3.Install and tighten nuts to secure mounting bracket.

Page 2 of 4

75.0131.05 20080606

Page 2
Image 2
BEA 10PBS45X, 10PBR45X, 10PBDGP1, 10EMSQ475X dimensions Precautions, Pre Installation Check, Hardwire Bracket - Optional