TITLE: MC-25 WITH ELECTRIC STRIKE,APT. BUZZER RELAY/ FIRE ALARM
A
NOTES: 1) JUMPERS JP1,JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS ON RELAY OUTPUT #2.
2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMINED BY CURRENT
DRAW OF ELECTRIC STRIKE.
4) BRIDGE RECTIFIER SUPPLIED BY OTHERS.
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY:
KJG KJG 80.0019.02
SCALE: DATE:
NONE 18 MAY 2005
PART NO:
SHEET
1 OF 1
COM
DOOR
CONTROL
ACT
RED COMMON
BLACK N/O

24 V

TRANSFORMER
COM
N/O
COM
N/O

OPTIONAL

BRIDGE
RECTIFIER
~~
+-
-
+
D/C ELECTRIC
STRIKE

VOLTAGE FOR

RELAY FROM

EXISTING APT.

BUZZER OR FIRE

ALARM SYSTEM

IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM