3Precautions

‰Shut off all power going to wall outlet before attempting any wiring procedures.

‰Maintain a clean & safe environment when working in public areas.

‰Constantly be aware of pedestrian traffic around the door area.

‰Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.

‰ESD electrostatic discharge: Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board ensure you dissipate your body’s charge.

‰Always check placement of all wiring before powering up to insure that moving door parts will not catch any wires and cause damage to equipment.

‰Ensure compliance with all applicable safety standards (i.e. ANSI A156.10 / A156.19) upon completion of installation.

‰DO NOT attempt any internal repair of the sensor. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair:

1.May jeopardize personal safety and may expose one to the risk of electrical shock.

2.May adversely affect the safe and reliable performance of the product will result in a voided product warranty.

4Pre-Installation Check

1.When wiring multiple devices together creating a system configuration, it is best to ensure that each device works independently. This will reduce troubleshooting if a discrepancy occurs.

2.Prior to installing any equipment in either new or existing circuits, ensure correct line voltage and line stability. Always remember to shut the power OFF before performing circuit wiring.

5Installation / Wiring / Setup

1

Installation

 

 

 

 

Adapter Ring

 



 

 



 

 

 

 

Foam Gasket

 

Gang Box

MS-08

Gang Box

MS-08

 

Metal or Plastic

Assembly

Metal or Plastic

Assembly

1.

The MS-08 may be mounted in conventional metal or plastic

2. Depending on the door installation, the weather resistant foam

 

electrical gang boxes. Make sure the unit sensor does not come in

gasket or the plastic adapter ring may be used. The weather

 

contact with the metal gang box to avoid shorting out the unit.

resistant foam is used as a protective barrier against the elements.

Do not place the sensor in the door’s opening range, where the

The plastic adapter ring is designed to enable the double gang face

plate to attach to various plastic and metal gang boxes.

 

sensor may see door movement.

 

 

 

Do not place moving objects in front of the sensor.

2

Wiring

 

 

 

 

 

 

 

M

 

• PWR: Black - 12 to 24 VAC / VDC: -5% to +10%

OC

 

 

 

S

 

• PWR: Red - 12 to 24 VAC / VDC: -5% to +10%

N

 

 

 

 

• NC: Empty - NC Contact

T

 

0

 

 

 

• NO: Green - NO Contact

R

 

8

 

 

 

• COM: White - Common at Door Control

O

 

 

 

L

 

 

 

 

1.Wire the 4-conductor cable to the door operator according to manufacturer specifications.

Page 2 of 3

 



Empty - NC Contact

Green - NO Contact

White - Com at Door Control

Red - 12 to 24 VAC / VDC

Black - 12 to 24 VAC / VDC

NC NO COM POWER

NC NO COMPOWER

 

 

 

2.Attach the 4-conductor cable connector to the Magic Switch.

75.5265.01 20071031

Page 2
Image 2
BEA MS-08 specifications Precautions, Pre-Installation Check, Installation / Wiring / Setup

MS-08 specifications

The BEA MS-08 is an advanced airborne radar system engineered for a variety of military applications, boasting cutting-edge technology and innovative features that enhance situational awareness and operational effectiveness. Developed by the renowned Belgian Aerospace company BEA, the MS-08 radar is designed to integrate seamlessly with modern defense systems while ensuring robust performance in diverse environments.

One of the standout features of the BEA MS-08 is its multi-mode capability, allowing it to adapt to different mission profiles. Whether it's for surveillance, reconnaissance, or targeting, the MS-08 can effortlessly switch modes, providing military operators with the flexibility to respond to real-time threats. The radar employs advanced signal processing techniques to filter out noise and enhance target detection and tracking. This results in improved accuracy and reliability in various weather conditions, making it a dependable asset for air force missions.

Moreover, the radar system is equipped with electronic scanning technology, enabling it to rapidly steer its beam to engage multiple targets with precision. This agility not only enhances its effectiveness in tracking fast-moving objects but also minimizes response time in critical scenarios. The system's high-resolution imaging capabilities allow operators to discern minute details from great distances, further solidifying its application in intelligence gathering.

Another significant characteristic of the BEA MS-08 is its compact and lightweight design. This feature allows for easier integration onto various platforms, including fixed-wing aircraft, helicopters, and unmanned aerial vehicles (UAVs). Additionally, the radar's modular construction simplifies maintenance and upgrades, ensuring it remains at the forefront of technological advancements throughout its operational lifecycle.

Security and cybersecurity are paramount in military operations, and the MS-08 possesses state-of-the-art encryption and anti-jamming features. These capabilities safeguard sensitive data while ensuring uninterrupted operation amidst electronic warfare scenarios.

In summary, the BEA MS-08 is a sophisticated airborne radar system that combines versatility, advanced technology, and high-performance characteristics. Its multi-mode functionality, rapid electronic scanning, compact design, and robust security features make it an essential tool for modern military operations, ensuring that armed forces are well-equipped to handle today's complex and dynamic threat landscape.