Installation/Operation/Maintenance

WARNING Professional Service Required.

Incorrect installation or misuse of this control could result in severe personal injury or death from heavy smoke, explosion or fire.

Please read and understand the manual supplied with this control. This control must be installed, adjusted and put into operation only by a qualified individual or service agency that is:

yLicensed or certified to install and provide technical service to oil heating systems.

yExperienced with all applicable codes, standards and ordinances.

yResponsible for the correct installation and commission of this equipment.

ySkilled in the adjustment of oil burners using combustion test instruments.

The installation must strictly comply with all applicable codes, authorities having jurisdiction and the latest revision of the National Fire Protection Association Standard for the Installation of Oil-Burning Equipment, NFPA 31 (or CSA-B139 and CSA-B140 in Canada) for stationary equipment.

Regulation by these authorities take precedence over the general instructions provided in this installation manual.

WARNING Explosion, Fire, Scald, & Burn Hazard

All heating equipment must have HIGH LIMIT controls to protect against excessive temperature and/or pressure.

The control must interrupt electrical power and shutdown the burner, if operating or safety controls fail and cause a runaway condition.

yFollow the equipment manufacturer’s wiring diagrams and note all required safety controls.

yTypical safety controls include high temperature or pressure limits, low water cutoffs, pressure relief valves and blocked flue sensing switches.

yVerify all limit and safety controls are installed and functioning correctly, as specified by the manufacturer, applicable safety standards, codes and all authorities having jurisdiction.

yInsure that the equipment is free of oil and oil vapor before starting or resetting the burner.

yDo not wire power directly to the burner motor. Only wire the motor as shown in Figure 2. If instant burner heat is required by the application, purchase or program a control with a long motor-off delay time, which will ensure instant heat if a new call for heat is received within the motor-off delay time.

WARNING ElectricalHazard Shock

Electrical shock can cause severe personal injury or death.

yDisconnect ALL electrical power to the equipment/burner circuit before installing or servicing this control.

yProvide ground wiring to the equipment, burner and metal control mounting box.

yPerform all wiring in compliance with the National Electrical Code ANSI/ NFPA 70 (Canada CSA C22.1).

Mounting:

Mount the control on a 4” x 4” junc- tion box on the burner, or inside the equipment cabinet. In replacement applications, mount the new control in the same location as the old control. In some replacement applications, it may be necessary to rotate the con- trol on the 4” x 4” box for best fit.

Mounting orientation: any orientation is acceptable with the exception of up-side down.

GeniSys Control 24V Control Installation and Operation Manual

3

Page 3
Image 3
Beckett 7559 Installation/Operation/Maintenance, Mounting, Electrical shock can cause severe personal injury or death

7559 specifications

Beckett 7559 is an advanced pump system designed for residential and commercial applications where efficient water management is essential. Known for its durability and reliability, the Beckett 7559 integrates several cutting-edge technologies, making it a popular choice among homeowners and industry professionals alike.

One of the standout features of the Beckett 7559 is its powerful motor, which is engineered to deliver high performance while maintaining energy efficiency. The motor operates at a low noise level, ensuring that the pump does not disrupt the tranquility of residential or garden environments. This makes it ideal for applications such as water fountains, ponds, and other water features where noise could be a concern.

The Beckett 7559 is equipped with a thermally protected motor that safeguards against overheating, extending the life of the pump and minimizing maintenance requirements. The unit also includes an integrated flow rate control, which allows users to customize water flow according to their specific needs. This feature not only enhances versatility but also optimizes water usage, contributing to eco-friendly practices.

Another remarkable characteristic of the Beckett 7559 is its robust construction. The pump is constructed with corrosion-resistant materials, ensuring that it can withstand exposure to various environmental factors, including water chemicals and changing weather conditions. This resilience makes the Beckett 7559 an excellent choice for use in tough outdoor conditions while maintaining aesthetic appeal.

The design of the Beckett 7559 also allows for easy installation and maintenance. The user-friendly interface ensures that even those with limited technical knowledge can set up and manage the pump with ease. Moreover, a variety of connectors and fittings are often included, making it compatible with a wide range of systems and configurations.

In summary, the Beckett 7559 stands out in the market for its powerful and energy-efficient motor, thermal protection features, customizable flow rate control, and durable construction. Designed for reliability and ease of use, it remains a top choice for effective water management in various applications. Whether for decorative ponds, fountains, or effective drainage solutions, the Beckett 7559 promises efficient performance and long-lasting use.