3Installation
3.1Drilling the Support surface and Fitting the Hood
Screw Fitting
For hoods without
•Fix the hood to the hanging unit using the screws 12f (3.5x16
Hood Type | 52 | 70 |
L1 | 497 | 677 |
Make a rectangular opening on the base of the hanging unit, leaving a minimum of 13 mm from the outer edges.
For hoods with
•Insert the hood until the side supports snap into place.
•Lock in position by tightening the screws Vf from underneath the hood.
3.2 Connection
3.2.1Ducted Version Air Exhaust System
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 120 or 150 mm, the choice of which is left to the installer.
•To install a ø 120 mm air exhaust connection insert the reducer flange 9 on the hood body outlet.
•Fix the pipe in position using sufficient pipe clamps (not supplied).
•Remove any activated charcoal filters.
Hood / User Manual | 7 / 11 EN |
|
|