Beko CDA751F, CDA752F manual internal light, trouble shooting, disposal

Models: CDA751F CDA752F

1 21
Download 21 pages 24.8 Kb
Page 19
Image 19
internal light

internal light

Should the light fail to work, proceed as follows.

1.Switch off at the socket outlet and pull out the mains plug.

• You may find it useful to remove shelves for easy access.

2.Use a flat tipped screwdriver to remove the light diffuser cover by inserting the blade in each of the two recesses to prise off each side.

3.First check that the bulb hasn’t worked loose by ensuring it is screwed securely in the holder. Replace the plug and switch on. If the bulb works, replace the light cover by inserting the rear lug and pushing up to locate the front two lugs.

4.If the light still fails to work, switch off at the socket outlet and pull out the mains plug. Replace the bulb with a new 15 watt (max) screw cap (SES) bulb.

5.Carefully dispose of the burnt-out light bulb immediately. Replacement light bulb can easily be obtained from a good local electrical or DIY store.

trouble shooting

If the appliance does not operate when switched on, check:

1The plug is inserted properly in the socket and that the power supply is on.

2The power supply to the socket by plugging in another appliance.

3The fuse has blown/circuit breaker has tripped/main distribution switch has been turned off.

4The temperature control has been set correctly.

5If you have changed the fitted moulded plug, ensure the new plug is wired correctly.

If the appliance is still not operating after the above checks, please refer to the section on how to obtain service.

Please ensure that the above checks have been made as a charge will be made if no fault is found.

disposal

If you are discarding an old refrigerator with a lock or latch fitted to the door, disable the lock/latch; ensure that it is left in a safe condition to prevent the entrapment of young children.

Do not dispose of any appliance on a fire. Your appliance contains non-CFC/HFC substances in the insulation and in the cooling system, which are potentially flammable if exposed to fire. We suggest you contact your local authority for disposal information and facilities available.

19

Page 19
Image 19
Beko CDA751F manual internal light, trouble shooting, disposal, Switch off at the socket outlet and pull out the mains plug