Water connection
•There are two different types of water inlet hoses:
-Cold water inlet hose (up to 25°C)
-Hot water inlet hose (up to 60°C)please check which one is applicable to your model.
If you are willing to connect your machine to natural
energy resources or to the central hot water supply, first check out whether your water inlet hose type is suitable by checking the temperature values written on the hose. If your hose is not suitable, apply to your authorized service to change the hose.
•The dishwasher may not be connected to open warm water devices or
Permitted water pressure:
Lowest permitted water pressure: 0.3 bars = 3 N/cm² = 30 kPa
When the water pressure is below 1 bar, please contact your technician.
Highest permitted water pressure: 10 bar = 100N/cm² = 1Mpa
When the water pressure is above 10 bars, a pressure reduction valve must be installed (available in trade supply stores).
Connect water inlet hose
Ensure that the water inlet hose is not bent or squeezed. Do not install a used hose set.
Use a
tap with a ¾ inch external thread. If required, use a filter insert to filter deposits from the pipes.
Check that the connection does not leak.
Important
For safety reasons, turn off the tap after every rinse process.
1009 |
AQUASAFE+ (some models) The Aquasafe+ System protects against water damage hich may be caused at the water inlet hose.
Do not immerse the system’s valve box into water; it contains electrical components.
In case of damage, pull out the power supply plug.
Do not shorten or lengthen the hose insert as it contains electrical cables and components.
����
������
1010
���������
GB