Note: The telnet setup procedure is the same as the serial
setup.
When the configuration is completed, remember to save and
restart.
Serial or Telnet Configuration
ePowerSwitch System is temporarily connected to a PC with a
terminal emulation package or through telnet connection. The
advantage of telnet configuration over serial port configuration is
telnet operation can be done anytime, but serial configuration
has a short five seconds login window when the NIC Web
Card starts up.
Approximately three seconds after you turn on the power for
ePowerSwitch, the NIC card displays “Check u-dram…”
Press “/” when you see “Waiting five seconds…” to enter
console configuration.
You are now ready to configure the ePowerSwitch.
Enter the user name and password.
Use CTRL-W to move up, CTRL-Z to move down. From this
menu you can select to enter the IP address, Gateway address,
and MIB system group; you can set trap receivers, display
settings; reset the settings to default values; save the new values
and exit the program, and exit without saving.
Use terminal to set IP, gateway and subnet
To set the IP address and Gateway address, select the first
item.