Troubleshooting
PROBLEM | POSSIBLE CAUSE | SOLUTION | |
|
|
| |
UPS not on | On/off/test/ button not | Press the on/off/test button | |
LED not lit | pushed or pushed less | more than 1 second | |
| than 1 second |
| |
|
|
| |
| Battery voltage less than | Recharge the UPS at least | |
| 10V | 4 hours | |
|
|
| |
| Load less than 20W | Normal condition | |
| at battery mode |
| |
|
|
| |
UPS always at | Power cord loose | Replug the power cord | |
battery mode |
|
| |
AC fuse is burned out | Replace the AC fuse | ||
| |||
|
|
| |
| Line voltage too high, too | Normal condition | |
| low or black out |
| |
|
|
| |
Back up time too short | Battery not fully charged | Recharge the UPS at | |
|
| least 4 hours | |
|
|
| |
The UPS continuously | Overload | Remove the | |
beeps |
| noncritical loads | |
|
|
| |
RED LED lit | Battery failure | Replace battery |
Storage
11.0Storage Conditions
Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least 4 hours. Disconnect any cables connected to the computer interface port to avoid unnecessary drainage of the battery.
11.1Extended Storage
During extended storage in environments where the ambient temperature is
During extended storage in environments where the ambient temperature is +30˚C to +45˚C (+86˚F to +113˚F), charge the UPS battery every 3 months.
Specifications
MODEL |
| F6C325 | F6C425 | F6C525 |
| F6C625 |
INPUT | Capacity | 325VA | 425VA | 525VA |
| 625VA |
| Voltage | 100V, 110V, 120V, ±25% |
|
|
| |
| Frequency | 50Hz or 60Hz ±5% (auto sensing) |
| |||
OUTPUT | Voltage | Simulated sine wave at Line Input ±5% | ||||
| (on battery) |
|
|
|
|
|
| Frequency | 50Hz or 60Hz ±0.5% |
|
|
| |
| (on battery) |
|
|
|
|
|
| Voltage | AVR automatically increases output voltage | ||||
| Regulation | 15% above input voltage if | ||||
| AVR | nominal. AVR decreases output voltage | ||||
|
| 13% below input voltage if +9% to |
| |||
|
| 25% of nominal |
|
|
| |
| Transfer Time | |||||
PROTECTION AND | Spike Protection | 320 Joules, 2ms |
|
|
| |
FILTERING | EMI/RFI filter | 10dB at 15MHz, |
|
|
| |
|
| 50dB at 30MHz |
|
|
| |
| Overload | UPS automatic shutdown if overload |
| |||
| Protection | exceeds 110% of nominal at 60 second | ||||
|
| and 130% at 3 seconds |
|
|
| |
| Unit Input | Fuse for overload and short circuit protection | ||||
| Network (UTP, RJ45) compatible jacks | |||||
| Cable Port | (F6C425, F6C525, F6C625) |
| |||
| Short Circuit | UPS output cut off immediately or input | ||||
|
| fuse protection |
|
|
| |
BATTERY | Type | Sealed, |
| |||
| Typical | 4 hours (to 90% of full capacity) |
| |||
| Recharge Time |
|
|
|
|
|
| Protection | Automatic | ||||
|
| replace battery indicator |
| |||
| Back up Time | Depending on computer load... |
| |||
|
|
| ||||
PHYSICAL | Net Weight | 4.7(10.4) | 5.8(12.8) | 6.2(13.7) |
| 6.5(14.3) |
| Kg(lbs) |
|
|
|
|
|
| Shipping Weight | 5.0(11.0) | 6.1(13.4) | 6.5(14.3) |
| 6.9(15.2) |
| Kg(lbs) |
|
|
|
|
|
| Dimension(mm) | 97x260x135 |
| 97x320x135 |
| |
| WxDxH |
|
|
|
|
|
| Input Inlet | IEC 320 power inlet |
|
|
| |
ALARM | Battery | Slow beeping sound (about 0.47Hz) |
| |||
|
|
|
|
|
| |
| Battery Low | Rapid beeping sound (about 1.824Hz) | ||||
| Overload | Continuous beeping sound |
| |||
INTERFACE | RS232 |
| ||||
| Interface | (F6C425, F6C525, F6C625) |
| |||
CONFORMANCE | Safety | cUL, TUV, CE, meet FCC |
| |||
| Surge | Meet IEEE 587 standard |
| |||
ENVIRONMENT | Ambient operation | 6,000 meters max. elevation, | ||||
|
|
| ||||
| Audible noise | <40dBA (1 meter from surface) |
| |||
| Storage condition | 15000 meters max. elevation |
|
14 | 15 |