Overview Side Panel
1.AC Input Power Cord (See #1 on Fig. 1) Provides power to your Battery Backup.
2.AC Breaker (Circuit Breaker; see #2 on Fig. 1)
Should a power overload occur, the circuit breaker triggers the unit to turn off AC power. To restore power, press the “circuit breaker” button to reset, then press the “Power” button.
3
3. USB Communication Port (See #3 on Fig. 1)
The unit features a USB communication port. Installation of the cable and the Bulldog Plus Software, which allows the unit to connect to your computer, is optional. The unit will provide backup power whether or not the cable and software are installed; however, without them you will be unable to utilize the data management product features.
Overview Alarms
Backup (Slow Alarm)
When the unit is in “backup” mode (running on battery), the YELLOW LED illuminates and the unit emits an audible alarm. The alarm stops when the unit returns to normal online operation.
Low Battery (Rapid Alarm)
In “backup” mode, when the battery energy runs low, the unit beeps rapidly until it either shuts down from a depleted battery or returns to normal online operation.
Fault (Continuous Alarm)
When the unit fails, it emits an audible alarm continuously to warn of a fault condition. Disconnect the equipment prior to checking it.
Overview Storage
Storage Conditions
Store the unit covered and upright in a cool, dry location with its battery fully charged. Before storing, charge the unit for at least twelve
(12)hours.
Extended Storage
During extended storage in environments where the ambient temperature is
Note:
Overview Technical Specifications
|
|
|
|
| F6H400ukUSB |
| F6H600ukUSB |
Model |
|
|
|
| F6H400exUSB |
| F6H600exUSB |
|
|
|
|
| F6H400evUSB |
| F6H600evUSB |
Capacity |
|
| VA/W |
| 400VA/200W |
| 600VA/300W |
|
|
| Voltage |
|
| 220/230/240VAC | |
Input |
| Frequency |
|
|
| 50/60Hz | |
| Max input current |
|
|
| 5A | ||
|
|
|
|
| |||
|
|
| Phase |
|
|
| Single |
|
| Voltage Range |
| 220/230/240VAC+10% | |||
Output |
| Frequency |
|
| 50Hz or 60Hz+1Hz | ||
(inverter Mode) |
| Max output current |
|
|
| 5A | |
|
| Waveform |
|
| Modified Sinwave | ||
Transfer Time |
|
| Typical |
|
|
| |
|
| Battery Type |
| 12V4.5Ahx1 |
| 12V5Ahx1 | |
| Backup Time at a PC load with monitor |
| |||||
Battery |
| (Typical 100W) |
|
| |||
|
|
|
|
| |||
|
| Recharging Time |
|
| 16 hours max | ||
|
|
| (recharge up to 90% capacity) | ||||
|
|
|
|
| |||
Display |
|
| LED |
| Power on, Backup, Fault | ||
|
| Battery Mode |
| Sounding every 5 seconds | |||
Audible Alarm |
| Low Battery |
| Sounding every second | |||
| Overload |
| Sounding every 0.5 second | ||||
|
|
| |||||
|
|
| Fault |
| Continuously Sounding | ||
Protection |
| Full Protection |
| Overload, Overcharge, Modem/Phone Line Surge | |||
|
| Protection and Short Circuit Protection | |||||
|
|
|
|
| |||
|
| Dimension (DxWxH) |
| 352mm*134mm*86mm | |||
Physical |
| Net Weight |
|
|
| 2.9KG | |
| Shucko | France |
| UK | 4 sockets for surge protection with battery backup | ||
Environment |
| Operation Temperature |
|
| |||
| Operation Humidity |
|
| ||||
|
|
|
|
All specifications are subject to change without prior notice.