2- UKOverview | Side Panel
1. AC Input Power Cord (See #1 on Fig. 1)
Provides power to your Bat tery Backup.
2. AC Breaker (Circuit Breaker; see #2 on Fig. 1)
Should a power overload o ccur, the circuit bre aker triggers th e unit to turn
off AC power. To restore power, press the “circuit breake r” button to res et,
then press the “Power” b utton.
3. USB Communication Port (See #3 on Fig. 1)
The unit features a USB communication po rt. Installatio n of the cable an d the Bulldog Plus Software, which allows the unit to c onnect
to your computer, is optional . The unit will pr ovide backup power w hether or not the cable and soft ware are installe d; however, without
them you will be unable to utilize the data m anagement produ ct features.
Overview | Alarms
Backup (Slow Alarm)
When the unit is in “bac kup” mode (running on battery), the YELLOW LED illuminates and the unit emi ts an audible ala rm. The alarm
stops when the unit retu rns to normal onl ine operation.
Low Battery (Rapid Alarm)
In “backup” mode, when th e battery ener gy runs low, the unit beeps rapidly u ntil it either shu ts down from a dep leted battery or returns
to normal online opera tion.
Fault (Continuous Alarm)
When the unit fails, it emits an audible alarm continuous ly to warn of a fau lt condition. Dis connect the equi pment prior to ch ecking it.
Overview | Storage
Storage Conditions
Store the unit covered an d upright in a co ol, dry locatio n with its batter y fully charged . Before storing, c harge the unit for at least twelve
(12) hours.
Extended Storage
During extended storag e in environments where the ambien t temperature is -15 en +30 °C, charge the unit’s battery ever y six (6)
months. During extende d storage in envir onments where the ambient tempera ture is +30 en 4 5 °C, charge the un it’s battery ever y
three (3) months.
Note:
Overview | Technical Specifications
All specifications are subject to change without prior notice.
Model
F6H400ukUSB
F6H400exUSB
F6H400evUSB
F6H600ukUSB
F6H600exUSB
F6H600evUSB
Capacity VA/W 400VA/200W 600VA/300W
Input
Voltage 220/230/240VAC
Frequency 50/60Hz
Max input current 5A
Phase Single
Output
(inverter Mode)
Voltage Range 220/230/240VAC+10%
Frequency 50Hz or 60Hz+1Hz
Max output current 5A
Waveform Modified Sinwave
Transfer Time Typical 2-6ms
Battery
Battery Type 12V4.5Ahx 1 12V5Ahx1
Backup Time at a PC load with monitor
(Typical 100W) 6-11 Minutes 10-15 Minutes
Recharging Time 16 hours max
(recharge up to 90% capa city)
Display LED Power on, Backup, Fault
Audible Alarm
Battery Mode Sounding every 5 seco nds
Low Battery Sound ing every secon d
Overload Sounding every 0.5 sec ond
Fault Continuously Sound ing
Protection Full Protection Overload, Overcharge, M odem/Phone Line Surge
Protection and Short Circuit Protection
Physical
Dimension (DxWxH) 352mm*134mm*86mm
Net Weight 2.9KG
Shucko France UK 4 sockets for surge protecti on with battery backup
Environment Operation Temperature 0-40oC
Operation Humidity 0-90%
3