Belkin P73446-B Page, Refer Servicing to, qualified service, personnel or contact

Models: P73446-B

1 2
Download 2 pages 5 Kb
Page 2
Image 2
P73446-B • Page 2
HARDWARE:
BAUD RATE - - - - - - - - - 2400 bps DATA LENGTH - - - - - - - - - - 8 bits STOP BIT - - - - - - - - - - - - - - 1 bit PARITY - - - - - - - - - - - - - - NONE

P73446-B • Page 2

UPS Uninterruptible Power Supply User Manual

USB Interface Port

1.

Firmware

Version of Firmware

2.

Rating VA

Rated Power Capacity of UPS

3.

Rating Voltage

Rated Power Voltage of UPS

4.

Rating Frequency

Connected Frequency Rating of UPS

5.

Rating Battery

Rated Battery Voltage Used by UPS

6.

Input Frequency

AC Utility Frequency

7.

Input Voltage

AC Utility Voltage

8.

Output Source

Indicating Bypass or On Battery

9.

Alarm

To Set Situation for Alarm

10. Voltage Sensitivity

To Improve Transfer Time and Avoid

 

 

Effect of I/P Distortion

11. Outlet Relay ON/OFF

Set Delay Time to Control Outlet Relay

 

 

On/Off

12. Next Shutdown

Time to Next Scheduled Shutdown

13. Next Restart

Time to Next Restart

14. AC Source

Input Power Source of UPS

15. Battery

Condition of Battery

16. Loading

Load Percentage of UPS

17. Battery Level

Indicates the Remaining Power

 

 

Percentage of Battery

18. Selectable Transfer Voltage

Change Transfer Voltage

19. Diagram

Input & Output Power Flow of UPS

20. Picture

General Outlook of UPS

RS232 Interface Port

RS232 Pin definition:

 

 

 

NC - - - - - - - - - - - - - - -

1

6 - - - - - - - - - - - - - - - -

NC

TXD - - - - - - - - - - - - - -

2

7 - - - - - - - - - - - - - - - -

NC

RXD - - - - - - - - - - - - -

3

8 - - - - - - - - - - - - - - - -

NC

NC - - - - - - - - - - - - - - -

4

9 - - - - - - - - - - - - - - - -

NC

Signal Ground - - - - - - -

5

 

 

*pin2: PC receives line RS232 data from UPS.

*pin3: PC transmits line RS232 data to UPS.

*pin5: signal ground.

*other: not used.

The RS232 communication port provides the following features:

1. Monitoring charger status

2. Monitoring battery status and condition

3. Monitoring inverter status

4.Monitoring UPS status

5.Monitoring the utility status

6.Providing the power switch function for the computer to turn on/off the utility on schedule. To save power, UPS data will be provided at 2400 baud rate and is made up of 8-bit, 1-stop-bit, and no parity-bit. All the information is provided in ASCII format.

CABLING:

 

 

 

COMPUTER

 

UPS

RX

(pin2)

TX

(pin2)

TX

(pin3)

RX

(pin3)

GND

(pin5)

GND

(pin5)

Battery Replacement

The average life of a battery is 3-5 years before ever needing to be replaced.

EcoPower Battery Replacement Program

In the event that the UPS needs a battery replacement, Belkin offers its EcoPower Battery Replacement Program. This program offers a battery replacement and full service check on your UPS to ensure it is working properly to protect your connected devices. It also ensures that the battery in the UPS is discarded properly in an effort to keep our environment clean. All participants in the program will receive a two-year extended product warranty. Please call Belkin Components for detailed information regarding the cost of the program and shipping procedures.

Battery Replacement

Battery replacement is a safe procedure. You may leave the UPS On and equipment connected during this procedure. Do not replace the battery when the UPS is “On Battery”. See page 15 for diagram illustrations.

1.Set the UPS at the edge of a table (Diagram A).

2.Slide the battery compartment cover down (Diagram B).

3.Grasp the tab attached to the battery and slide the battery partially out. Then grab the battery firmly and remove; the battery wires will disconnect as the battery is pulled out (Diagram C).

4.Carefully insert the new battery halfway into the UPS. Avoid pinching the wires (Diagram D).

5.Connect the wires to the new battery according to the following configuration:

Red wire to red terminal Black wire to black terminal

6.Carefully insert the battery terminals.

7.Slide the battery compartment cover back into place (Diagram E).

The old battery must be recycled. Deliver the battery to an appropriate recycling facility or return it to Belkin in the packing carton that came with your new battery. Additional recycling information is provided with your new battery.

Battery Replacement (continued)

Refer Servicing to

Diagram A

qualified service

 

personnel or contact

 

Belkin Components.

 

Diagram B

Diagram C

Slide the battery

Slide the battery

compartment cover.

partially out.

 

Diagram D

Diagram E

Slide the battery back in.

Slide the battery

Avoid pinching

cover into place.

the wires.

 

Troubleshooting

PROBLEM

POSSIBLE CAUSE

SOLUTION

 

 

 

UPS not on

On/off/test/button not pushed or

Press the on/off/test button

LED not lit

pushed less than 3 seconds

more than 3 seconds

 

 

 

 

Battery voltage less than 10V

Recharge the UPS at least

 

 

4 hours

 

 

 

 

UPS fault

Contact service personnel

 

 

 

UPS always at

Power cord loose

Replug the power cord

battery mode

 

 

AC breaker is burned out

Replace the breaker

 

 

 

 

 

Line voltage too high, too low,

Normal condition

 

or black out

 

 

 

 

Back-up time too short

Battery not fully charged

Recharge the UPS at least

 

 

4 hours

 

 

 

 

UPS is overloaded

Remove some unnecessary

 

loads

 

 

 

 

 

Charger fault or

Replace battery

 

other reason

 

 

 

 

The UPS continuously

Overload

Remove the non-critical loads

beeps

 

 

 

 

 

Red LED lit

Battery failure

Replace battery

 

 

 

Storage

11.0Storage Conditions

Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least 4 hours. Disconnect any cables connected to the computer interface port to avoid unnecessary drainage of the battery.

11.1Extended Storage

During extended storage in environments where the ambient temperature is -15°C to +30°C, charge the UPS battery every 6 months.

During extended storage in environments where the ambient temperature is +30°C to +45°C, charge the UPS battery every 3 months.

Specifications (USB Series)

CE Declaration of Conformity

We, Belkin Components, declare under our sole responsibility that the F6C325u- 220V, F6C425u-220V, F6C525u-220V, F6C625u-220V, to which this declaration relates, is in conformity with Generic Emissions Standard EN50081-1 and with Generic Immunity Standard EN50082-1 1992 to which this declaration relates, is in conformity with Generic Emissions Standard EN50081-1 and with Generic Immunity Standard EN50082-1 1992.

Belkin Components Two-Year Product Warranty

Belkin Components warrants this product against defects in materials and workmanship for two years. If a defect is discovered, Belkin will, at its option, repair or replace the product at no charge, provided it is returned during the warranty period, with transportation charges prepaid, to the authorized Belkin dealer from whom you purchased the product. Proof of purchase may be required.

This warranty does not apply if the product has been damaged by accident, abuse, misuse, or misapplication; if the product has been modified without the written permission of Belkin; or if any Belkin serial number has been removed or defaced.

THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE IN LIEU OF ALL OTHERS, WHETHER

ORAL OR WRITTEN, EXPRESSED OR IMPLIED. BELKIN SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

No Belkin dealer, agent, or employee is authorized to make any modification, extension, or addition to this warranty.

BELKIN IS NOT RESPONSIBLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPROGRAMMING, OR REPRODUCING ANY PROGRAM OR DATA STORED IN OR USED WITH BELKIN PRODUCTS.

Specifications

RS232 Series

MODEL

 

325VA

425VA

525VA

625VA

INPUT

Capacity

325VA(211W)

425VA(255W)

525VA(315W)

625VA(375W)

 

Voltage

187 Vac - 280 Vac

 

 

 

 

Frequency

50Hz or 60Hz ±3Hz (auto sensing)

 

 

OUTPUT

Voltage

Simulated sine wave, 230Vac±8%

 

 

 

(on battery)

 

 

 

 

 

Frequency

50Hz or 60Hz ±1Hz

 

 

 

(on battery)

 

 

 

 

 

Voltage

Smart boost increases 14.8% of voltage if input is 213 to 187 Vac.

 

Regulation

 

 

 

 

 

AVR

Smart trim reduces 12.8% of voltage if input is 247 to 280 Vac

 

 

 

 

 

 

 

 

 

Transfer Time

< 4 milliseconds, including detection time

 

PROTECTION

Spike Protection

150 Joules

 

 

 

AND FILTERING

Overload Protection

UPS automatic shutdown if overload exceeds 130% in AC mode and

 

 

100% in back-up mode. UPS alarms continuously in > 107% or

 

 

<130% in AC mode.

 

 

 

 

 

 

 

 

 

Unit Input

Breaker for overload and short circuit protection

 

 

Modem/Network

Single Line (2-Wire, RJ11) Network (UTP, RJ45) compatible jacks, one

 

 

input/two output except F6C325 (Series)

 

 

Short Circuit

UPS output cut off immediately or input breaker protection

 

 

 

 

 

 

BATTERY

Type

Sealed, maintenance-free lead acid

 

 

 

Typical

4 hours (to 90% of full capacity)

 

 

 

Recharge Time

 

 

 

 

 

 

 

 

Protection

Automatic self-test and discharge protection, replace

 

 

 

battery indicator

 

 

 

 

Back-up Time

Depending on computer load...

 

 

 

Full/half load

5-17 min

5-24 min.

5-32 min

5-41 min.

PHYSICAL

Net Weight

5.5kg/12.3lbs.

6kg/13.23lbs

6.5kg/14.33lbs.

 

Dimension

11.4"x9.6"x12.8"

 

 

 

 

 

 

 

 

(mm) WDH

 

 

 

 

 

Input inlet

10A/250V*1pcs, EN60320

 

 

 

Output outlet (UPS)

10A/250V*4pcs; EN60320/F

 

 

 

Output outlet (Bypass)

10A/250V*4pcs; EN60320/F

 

 

 

 

 

 

 

 

ALARM

Battery Back-Up

Slow beeping sound (about 15 sec. interval)

 

 

Battery Low

Rapid beeping sound (about 1 sec. interval)

 

 

Overload

Continuous beeping sound (about 1 sec. interval)

 

 

Fault

10 sec. beeping sound continuously

 

 

 

Battery test

Slow beeping sound (about 15 sec. interval)

 

INTERFACE

RS232 Interface

RS232 Port (except F6C325-Series)

 

 

CONFORMANCE

Safety

CE, TUV, BSI, NF

 

 

 

 

Surge

Meet IEEE C62.41. Category A standard

 

ENVIRONMENT

Ambient operation

0~95%, humidity non-condensing, 0~40°C

 

 

Audible noise

<40dBA (1 meter from surface)

 

 

 

Storage condition

-15°C – 40°C (with battery)

 

 

 

 

-15°C – 70°C (without battery)

 

 

 

 

 

 

 

 

USB Series

MODEL

 

350VA

 

 

500VA

 

650VA

INPUT

Capacity

350VA(277W)

 

500VA(300W)

 

650VA(390W)

 

Voltage

187 Vac - 280 Vac

 

 

 

 

 

 

 

Frequency

50Hz or 60Hz ±3Hz (auto sensing)

 

 

 

 

OUTPUT

Voltage

Simulated sine wave, 230 Vac±8%

 

 

 

 

 

(on battery)

 

 

 

 

 

 

 

 

Frequency

50Hz or 60Hz ±1Hz

 

 

 

 

 

(on battery)

 

 

 

 

 

 

 

 

Voltage

Smart boost increases 14.8% of voltage if input is 213 to 187 Vac.

 

Regulation

 

 

 

 

 

 

 

 

AVR

Smart trim reduces 12.8% of voltage if input is 247 to 288 Vac

 

 

 

 

 

 

 

 

 

 

 

Transfer Time

< 4 milliseconds, including detection time

 

PROTECTION

Spike Protection

150 Joules

 

 

 

 

 

 

AND FILTERING

Overload Protection

UPS automatic shutdown if overload exceeds 130% in AC mode and

 

 

100% in back-up mode. UPS alarms continuously in > 107% or

 

 

<130% in AC mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Input

Breaker for overload and short circuit protection

 

 

Modem/Network

Single Line (2-Wire, RJ11) Network (UTP, RJ45) compatible jacks, one

 

 

input/two output

 

 

 

 

 

 

 

Short Circuit

UPS output cut off immediately or input breaker protection

 

 

 

 

 

 

 

 

 

BATTERY

Type

Sealed, maintenance-free lead acid

 

 

 

 

 

Typical

4 hours (to 90% of full capacity)

 

 

 

 

 

Recharge Time

 

 

 

 

 

 

 

 

 

 

 

 

 

Protection

Automatic self-test and discharge protection, replace

 

 

 

battery indicator

 

 

 

 

 

 

 

Back-up Time

Depending on computer load...

 

 

 

 

 

Full/half load

5-20 min

5-30 min.

 

5-45 min

 

PHYSICAL

Net Weight

5.5kg/12.3lbs.

6kg/13.23lbs

 

6.5kg/14.33lbs.

 

Dimension

11.4"x9.6"x12.8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(mm) WDH

 

 

 

 

 

 

 

 

Input inlet

10A/250V*1pc, EN60320

 

 

 

 

 

Output outlet (UPS)

10A/250V*4pcs; ENG60320/F

 

 

 

 

 

Output outlet (Bypass)

10A/250V*4pcs; ENG60320/F

 

 

 

 

 

 

 

 

 

 

 

 

ALARM

Battery Back-Up

Slow beeping sound (about 15 sec. interval)

 

 

Battery Low

Rapid beeping sound (about 1 sec. interval)

 

 

Overload

Continuous beeping sound (about 1 sec. interval)

 

 

Fault

10 sec. beeping sound continuously

 

 

Battery test

Slow beeping sound (about 15 sec. interval)

 

INTERFACE

USB Interface

USB Port

 

 

 

 

 

 

CONFORMANCE

Safety

CE, TUV, BSI, NF

 

 

 

 

 

 

 

Surge

Meet IEEE C62.41. Category A standard

 

ENVIRONMENT

Ambient operation

0~95%, humidity non-condensing, 0~40°C

 

 

Audible noise

<40dBA (1 meter from surface)

 

 

 

 

 

Storage condition

-15°C – 40°C (with battery)

 

 

 

 

 

 

-15°C – 70°C (without battery)

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 2
Image 2
Belkin P73446-B Page, Refer Servicing to, qualified service, personnel or contact, Belkin Components