TechnicalBulletin
Bulletin No.: | Effective Date: 7/20/77 | Cancels: N/A | Page: 1 of 2 |
Subject: ASA-1 AUTOMATIC SLACK ADJUSTER
The
The primary purpose of this bulletin is to notify you of some important service information.
A. Loose Linkage Nuts
We have received some reports of loose linkage nuts where the linkage is fastened to the arm of the bell crank.
Because of the importance of this, we request that you check all units in stock. The procedure is short and simple, and the procedure is as follows: