MAINTENANCE OF THE MACHINE

CHANGING THE PARTS

Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply.

To replace different components such as burners, taps and electrical parts you must take out the hob from the kitchen unit by releasing the fixing hooks, unscrew the fixing screws of the burners on the work top, unscrew the fixing nuts of the electric plates which are visible on the lower part of the hob and remove the worktop in order to carry out the replacement of the defective parts.

NOTE: If the taps need replacing you also need to unscrew the two fixing screws of the gas ramp at the bottom of the hob which are found on the upper part of the latter.

For appliances equipped with automatic “ON” switches you must dismantle the “ON” switch chain before replacing the taps.

You are advised to change the seal on the tap every time you replace a tap in order to ensure a perfect hold between the body and ramp.

WARNING: The electric cable which is provided with the appliance is connected to the appliance with a type X connection and thus can be replaced with the same type of cable as that installed without using special tools. In the event of wear or damage to the mains cable, replace it with :

Type/ section of mains cable H05VV-F 3x0,75 mm2 or H05RR-F 3x0,75 mm2

WARNING: If you replace the electric mains cable the installer must have the earth conductor about 2 cm longer than the phase conductors and must also take heed of the warnings regarding electric connection.

Room ventilation – Location and venting.

ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in conformity with the national standards in force.

ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be installed in conformity with the national standards in force.

-CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: To change the nozzles of the burners use the following procedure:

Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE A shown below.

TABLE N°2: Adapting to different types of gas

 

 

 

APPLIANCE CATEGORY:

III

 

Burner

Type of Gas

Pressure

Nozzle

 

Nominal Charge

Reduced Charge

Diameter

 

 

 

 

diameter

 

 

 

 

 

 

 

 

by-pass 1/100mm

 

 

 

mbar

1/100mm

g/h

l/h

Kw

 

kcal/h

kw

 

kcal/h

 

 

Town

G110

8

145

-

227

1,00

 

860

0,30

 

258

27 reg

Auxiliary

Natural

G20

20

77

-

95

1,00

 

860

0,30

 

258

27 reg

 

Butane

G30

28

50

73

-

1,00

 

860

0,30

 

258

27

 

Propane G31

37

50

71

-

1,00

 

860

0,30

 

258

27

 

Town

G110

8

192

-

397

1,75

 

1505

0,44

 

378

31 reg

Semi-

Natural

G20

20

101

-

167

1,75

 

1505

0,44

 

378

31 reg

Rapid

Butane

G30

28

66

127

-

1,75

 

1505

0,44

 

378

31

 

Propane G31

37

66

125

-

1,75

 

1505

0,44

 

378

31

 

Town

G110

8

280

-

681

3

 

2580

0,75

 

645

42 reg

 

Natural

G20

20

129

-

286

3

 

2580

0,75

 

645

42 reg

Rapid

Butane

G30

28

87

218

-

3

 

2580

0,75

 

645

42

 

Propane G31

37

87

214

-

3

 

2580

0,75

 

645

42

 

Town

G110

8

130

-

181

0,8

 

688

0,30

 

258

27 reg

Dual

Natural

G20

20

70

-

76

0,8

 

688

0,30

 

258

27 reg

burner

Butane

G30

28

46

211

-

0,8

 

688

0,30

 

258

27

inner

Propane G31

37

46

207

-

0,8

 

688

0,30

 

258

27

 

Town

G110

8

2x300

-

885

4,4

3784

1.8

 

1548

65 reg

Dual

Natural

G20

20

2x110

-

419

4,4

3784

1.8

 

1548

65 reg

burner

Butane

G30

28

2x69

298

-

4,1

3526

1.8

 

1548

65

outer

Propane G31

37

2x69

293

-

4,1

3526

1.8

 

1548

65

CAUTION: save the orifices removed from the appliance for future use

Regulation of burners

Regulation of the "MINIMUM" on the burners

To regulate the minimum on the burners carry out the following procedure indicated below:

1)Turn on the burner and put the knob onto position MINIMUM ( small flame ).

2)Remove the knob ( Fig. 10) of the tap which is set for standard pressure. The knob is found on the bar of the tap itself.