PREPARE THE HOOD (CONTINUED)

PLENUM

NON-DUCTED CONFIGURATION ONLY

7.Carefully place the lower flue into the recessed area of the range hood.

8.Carefully slide the upper flue down inside the lower flue.

9.Secure the recirculation plenum to the upper flue with (4) flat head screws.

UPPER

FLUE

WIRING

Note: This range hood must be properly grounded. The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes.

1.Remove the wiring box cover. Remove a knockout from the wiring box.

2.Feed 6" of power cable through the knock- out opening and secure cable to the wiring box with an appropriate connector.

3.Make electrical connections. Connect white to white, black to black and green to green.

4.Replace wiring box cover and screws. Make sure that wires are not pinched be- tween cover and box.

WIRING BOX

COVER

DUCT COLLAR

- 10 -