OPERATION
Controls
The hood is operated using the (4) push- buttons located at
The light switch turns the halogen lamps on and off.
The blower
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| BLOWER |
| BLOWER |
|
| |||
|
| HIGH |
|
| ||||
| OFF |
|
| SPEED |
|
| ||
| SWITCH |
|
|
|
|
| ||
|
|
| BLOWER |
|
| |||
LIGHT | PILOT | |||||||
MEDIUM | ||||||||
SWITCH | LAMP | |||||||
| SPEED | |||||||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
The blower medium speed switch changes the blower speed to medium. This switch works only if the blower is already running at low or high speed.
The blower high speed switch changes the blower speed to high. This switch works only if the blower is already running at low or medium speed.
The pilot lamp lights up whenever the blower is on.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.
1)If blower is OFF - it turns blower ON to HIGH speed.
2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.
HALOGEN BULBS
This range hood requires two halogen bulbs (Type JC, 12Volt, 20Watt Max,
ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.
To change bulbs:
1.Loosen the ring nut by turning it counterclockwise.
2.Remove the bulb by pulling sideward (DO
NOT ROTATE). CAUTION: BULB MAY BE
HOT!
RING NUT
3.Replace with Type JC, 12Volt, 20Watt Max,
-12 -